Troubleshooting
Cabinet Temperature Is too warm.
Cabinet is noisy.
REFERENCE
Item Number
Model Number
50038
BB-CN-0005-HC
50039
BB-CN-0014-HC
50040
BB-CN-0017-HC
50041
BB-CN-0026-HC
Thermostat set too warm.
Blocking air flow.
Excessive amount of warm product
Placed in cabinet.
Fuse blown or circuit breaker
tripped.
Dirty condenser coil.
Prolonged door opening or door
ajar.
Evaporator coil iced over.
Loose part(s).
Tubing vibration.
For service call 1-800-465-0234.
Description
Cooler Back Bar 5 cu ft Reach In
115V/60/1 ETL cETLus INTERTEK
Cooler Back Bar 13.5 cu ft Reach In
115V/60/1 ETL cETLus INTERTEK
Cooler Back Bar 17.2 cu ft Reach In
115V/60/1 ETL cETLus INTERTEK
Cooler Back Bar 25.8 cu ft Reach In
115V/60/1 ETL cETLus INTERTEK
10
Set thermostat to lower
Temperature.
Re-arrange product to allow for
Proper air flow. Make sure there
Is at least four inches of clearance
from evaporator.
Allow adequate time for product to
cool down.
Replace fuse or reset circuit
breaker.
Clean the condenser coil.
Ensure doors are closed when not
in use. Avoid opening doors for
long periods of time.
(See above)
Locate and tighten loose part(s).
Ensure tubing is free from contact
with other tubing or components.
Manufacturer Model Number
JBC-25-HC
JBC-50-HC
JBC-65-HC
JBC-95-HC