 Relationship between the analog input terminal function and the calibration parameter
Pr.868
Terminal function
setting
Auxiliary frequency (speed)
0
setting
2
Regenerative driving torque limit
4
Torque limit
9999
(initial
No function
value)
 Changing the frequency for the maximum analog input (C14 (Pr.918))
• Use C14 (Pr.918) to only change the frequency setting (gain) for the maximum analog input voltage. (The C12 (Pr.917), C13
(Pr.917), and C15 (Pr.918) settings need not be changed.)
42
CONTROL CIRCUIT INPUT SIGNAL
Bias setting
C12 (Pr.917) Terminal 1 bias frequency
(speed)
C13 (Pr.917) Terminal 1 bias (speed)
C16 (Pr.919) Terminal 1 bias command
(torque)
C17 (Pr.919) Terminal 1 bias (torque)
Calibration parameter
Gain setting
C14 (Pr.918) Terminal 1 gain frequency
(speed)
C15 (Pr.918) Terminal 1 gain (speed)
C18 (Pr.920) Terminal 1 gain command
(torque)
C19 (Pr.920) Terminal 1 gain (torque)