Troubleshooting - Hilti DX 351 M&E Manual

Hide thumbs Also See for DX 351 M&E:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 23
5. Lift the fastening tool away from the working surface.
6. Position the fastening tool at the next point and repeat the steps.
7

Troubleshooting

DANGER
Risk of injury by unsecured fastening tool! If the fastening tool jams in the compressed state or if a
cartridge does not fire, the fastening tool might be loaded with the safety off. Unintentional triggering can
cause severe injuries.
▶ At all times, make sure that the fastening tool is not pointing toward you or anyone else.
▶ Make sure that the fastening tool cannot be fired accidentally and do not hold your hand in front of the
muzzle of the fastener guide.
▶ Keep a fastening tool with the safety off under observation at all times.
▶ Free the jammed components. → page 25
▶ After 2-3 misfires, i.e. no clearly audible firing sound and fasteners are not driven or not driven adequately,
please proceed as follows: → page 26
▶ If a cartridge does not fire, proceed as follows: → page 25
7.1
Fastening tool jams and does not extend
DANGER
Risk of injury by unsecured fastening tool! If the fastening tool jams in the compressed state or if a
cartridge does not fire, the fastening tool might be loaded with the safety off. Unintentional triggering can
cause severe injuries.
▶ At all times, make sure that the fastening tool is not pointing toward you or anyone else.
▶ Make sure that the fastening tool cannot be fired accidentally and do not hold your hand in front of the
muzzle of the fastener guide.
▶ Keep a fastening tool with the safety off under observation at all times.
1. Keep the fastening tool pressed against the work surface for at least 30 seconds and trigger the fastening
tool again.
2. Lift the fastening tool away from the working surface.
Be sure not to point it toward yourself or other persons!
3. Try to pull the fastener guide to its initial position by hand.
Take your hand off the trigger and do not hold your hand in front of the muzzle!
4. Immediately pull the cartridge strip out of the fastening tool.
If the cartridge strip cannot be removed:
▶ Allow the fastening tool to cool down at a safe location under observation.
▶ At all times, make sure that the fastening tool is not pointing toward you or anyone else.
▶ Contact Hilti Service.
5. Service the tool. → page 27
7.2
Cartridge does not fire when fastening tool is above operating temperature
At all times, make sure that the fastening tool is not pointing toward you or anyone else!
If a cartridge does not fire, proceed as follows:
1. Keep the fastening tool pressed against the work surface for at least 30 seconds and trigger the fastening
tool again.
2. If the cartridge still does not fire, wait for 30 seconds and then lift the fastening tool away from the work
surface.
3. Immediately pull the cartridge strip out of the fastening tool.
▶ If the cartridge strip cannot be removed:
▶ Allow the fastening tool to cool down at a safe location under observation.
▶ Contact Hilti Service.
4. Service the tool. → page 27
5. Move the cartridge to a safe location.
6. Dispose of the cartridges that have not fired.
▶ Comply with the locally applicable disposal regulations.
*332581*
332581
English
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dx 351 mx

Table of Contents