Figure 37
1. Jam nut
6.
Loosen or tighten the turnbuckle that adjusts the
tension on the cable
7.
Adjust the turnbuckle until you obtain the proper
gap.
8.
Tighten the jam nut.
9.
Insert the 2 screws that you previously removed
on the belt cover.
10.
If the auger/impeller cable is properly adjusted
but a problem remains, contact an Authorized
Service Dealer.
2. Turnbuckle
(Figure
37).
Checking the
Auger-Gearbox-Oil Level
Service Interval: Yearly—Check the auger-gearbox
1.
Move the machine to a level surface.
2.
Clean the area around the pipe plug and remove
the pipe plug from the gearbox
Note:
If needed, use pliers to assist in removing
the pipe plug.
g260109
3.
Check the oil level using a suitable measuring
device, such as a clean cable tie. The oil should
be approximately 3.8 cm (1.5 inches) below the
filler opening
4.
If the oil level is low, add GL-5 or GL-6, SAE
85-95 EP gear oil lubricant to the gearbox, then
check the oil level again.
Note:
Do not use synthetic oil.
5.
Install the pipe plug in the gearbox.
23
oil and add oil if necessary.
(Figure
Figure 38
(Figure
39).
Figure 39
38).
g257725
g257737