Carrier AquaEdge 19XR Start-Up, Operation And Maintenance Instructions Manual page 121

Single stage and two-stage semi-hermetic centrifugal liquid chillers with pic 6 controls and r-134a/r-513a 50/60 hz
Table of Contents

Advertisement

19XR PIC 6 ISM CONFIGURATION TABLE (CONF_ISM) CONFIGURATION SHEET
(Must be configured for all fixed speed machines with ISM, Benshaw MX3, freestanding VFD)
DESCRIPTION
Communication Timeout
Starter Type
0 = Full Volt 1 = Reduced Volt
2 = Solid State 3 = FS VFD
Single Cycle Dropout
Motor Rated Load Amps
Motor Rated Kilowatts
Motor Locked Rotor Trip
Locked Rotor Start Delay
Starter LRA Rating
Motor Rated Line Voltage
Current Imbal Threshold
Voltage Imbal Threshold
Motor Current CT Ratio:1
Volt Transformer Ratio:1
Current Imbal Persist
Voltage Imbal Persist
Line Frequency Faulting
Frequency (NO = 50 Hz, YES = 60 Hz)
Ground Fault Protection
Ground Fault Current
Ground Fault Persistence
Ground Fault Start Delay
Ground Fault CT Ratio:1
Overvoltage Threshold
Undervoltage Threshold
Over Under Volt Persist
Under Volt Start Delay
19XR PIC 6 General VFD Config (CFGGEVFD) CONFIGURATION SHEET
DESCRIPTION
VFD Current Limit
DESCRIPTION
Compressor Speed 100%
Rated Line Voltage
Motor Nameplate Current
Motor Rated Load Current
Motor Nameplate Voltage
Motor Nameplate RPM
Motor Nameplate KW
Skip Frequency 1
Skip Frequency 2
Skip Frequency 3
Skip Frequency Band
Motor Rated Load Current
Increase Ramp Time
Decrease Ramp Time
Line Voltage Imbalance%
Line Volt Imbalance Time
Line Current Imbalance%
Line Current Imbal Time
Motor Current Imbalance%
Motor Current Imbal Time
Single Cycle Dropout
PWM Switch Frequency
0=2KHZ, 1=4KHZ
RANGE
0 to 255
0 to 3
DSABLE/ENABLE
10 to 5000
1000 to 8000
100 to 65535
1 to 10
100 to 65535
200 to 13800
5 to 100
1 to 10
3 to 1000
1 to 115
1 to 10
1 to 10
DSABLE/ENABLE
NO/YES
DSABLE/ENABLE
1 to 25
1 to 10
1 to 20
150 to 150
105 to 115
85 to 95
1 to 10
1 to 4
(Must be configured for all machines with VFD
RANGE
0 to 99999
UM VFD Configuration
RANGE
47 to 110
200-13800
10 to 2000
10 to 2000
200 to 13800
1500 to 3600
0 to 5600
0.0 to 102.0
0.0 to 102.0
0.0 to 102.0
0.0 to 102.0
10 to 1500
5 to 60
5 to 60
1 to 10
1 to 10
5 to 40
1 to 10
5 to 40
1 to 10
0 to 1
0 to 1
CL-5
UNITS
DEFAULT
sec
10
0
DSABLE
amps
200
kW
1500
amps
1000
cycles
5
amps
2000
volts
460
%
15
%
5
100
1
sec
5
sec
5
DSABLE
NO
ENABLE
amps
15
cycles
5
cycles
10
150
%
115
%
85
sec
5
sec
1
UNITS
DEFAULT
amps
250
UNITS
DEFAULT
Hz
50
V
460
AMPS
200
AMPS
200
Volts
460
rpm
3000
KW
1500
Hz
102
Hz
102
Hz
102
Hz
0
AMPS
200
sec
30
sec
30
%
10
sec
10
%
40
sec
10
%
40
sec
10
0
0
VALUE
VALUE
VALUE