Riello 466 M1 Installation, Use And Maintenance Instructions page 45

Heavy oil burners
Table of Contents

Advertisement

Available languages

Available languages

3.3
ELECTRICAL CONNECTIONS TO THE BURNER TERMINAL STRIP
(to be carried out by the installer)
H
Remote lock-out signal
IN
Optional switch on-off burner
MB Burner terminal strip
PS
Reset push - button
SA High temperature oil alarm
NOTE:
Check the lock-out by darkening the flame sensor after removal of the cover.
ATTENTION HIGH VOLTAGE.
In case of supply 230V without neutral, connect the motor and the pre-heater thank through delta (the "star"
connection is the original one, made for 400V).
NOTE 
In systems where the run of wiring connecting the thermostat exceeds 20 metres in length, or in places where
the burner is subject to particularly disturbing electromagnetic interference (over 10 v/m), you must insert the
relay-interface kit item number 3010386.
2915842
A Ampere
B Ampere
C mm
D mm
TL
Limit control device system
TS
Safety control device system
T2
Load control system for 2
Load control system for 3
T3
7
GB
D2619
230V
400V
T25
T25
T50
T35
2
2,5
2,5
2
10
6
nd
stage
rd
stage