SUN600-(5KTL, 6KTL)-L0
User Manual
Parameter Name
High feed-in power duration threshold for
triggering inverter shutdown
Note a: This parameter is supported only for the AS4777 grid code.
----End

7.2.1.2 Apparent Power Control on the Inverter Output Side

On the home screen, tap Settings > Power adjustment to set inverter
parameters.
Figure 7-7 Apparent power control
Issue 04 (2023-02-17)
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interaction
Description
The default value is 20. This
parameter specifies the duration
threshold of high feed-in power for
triggering inverter shutdown.
● When High feed-in power
duration threshold for triggering
inverter shutdown is set to 5,
Shutdown at high feed-in power
takes precedence.
● When High feed-in power
duration threshold for triggering
inverter shutdown is set to 20,
Limited feed-in takes precedence
(when Active power control is set
to Limited feed-in).
69