Static Mixer Assembly - Graco FUSION 248597 Instructions-Parts List Manual

Solvent purge plural component gun
Table of Contents

Advertisement

Static Mixer Assembly

1.
Follow Pressure Relief Procedure, page 18.
2.
Flush Gun, page 23.
3.
Disconnect air (D) and remove fluid manifold (G).
40
G
9, 63
4.
Disassemble RAC tip, guard (9, 63) and static
mixer (40) from solvent purge assembly (28).
28
40
9, 63
5.
Disassemble static mixer housing (40a), mixer
(40b), gasket (40c), packing (40d), and adapter
(41). Inspect parts for damage, replace if neces-
sary.
40a
40d
41
310648E
D
TI4968a
TI5033a
40c
40b
6.
Reassemble static mixer assembly (40a-e).
7.
Reassemble RAC tip, guard (9, 63) and static
mixer (40) from solvent purge assembly (28).
28
40
9, 63
8.
Attach fluid manifold. Connect air. Return gun to
service.
Repair