Setup - Graco FUSION 248597 Instructions-Parts List Manual

Solvent purge plural component gun
Table of Contents

Advertisement

Setup

1.
Read Hand Drilling of Mix Modules, page 14,
before performing setup procedure.
2.
Assemble gaskets (40c), static mixer assembly
(40), o-ring (40d), adapter (41), and RAC tip and
guard (9, 63) assembly to fluid housing on front
end of gun.
40
41
40d
9, 63
Solvent purge knob (V) and inlet (Y) can be
rotated in any direction.
3.
Close fluid valves A and B.
4.
Connect A (ISO) and B (RESIN) fluid hoses to fluid
manifold (G).
G
12
40c
Y
V
TIv033a
TI2411A
B (RESIN)
TI2417A
A (ISO)
5.
Engage piston safety lock (L), page 8.
L
6.
Connect gun air whip hose (T) and air valve (U) to
main air hose. Attach fluid manifold (G) to gun.
G
To change position of fluid manifold or use
optional fluid inlets, see pages 20 and 21.
7.
Connect air line to quick coupler (D). Turn on air.
Open air valve (U). Air valve (K) should be screwed
tight. There is no clean off air to adjust on the sol-
vent purge gun.
To use optional air inlet (J), see page 21.
Setup
TI3850a
T
U
TI4968a
K
U
D
TI4969a
J
310648E