Piston Safety Lock; Air Valve - Graco FUSION 248597 Instructions-Parts List Manual

Solvent purge plural component gun
Table of Contents

Advertisement

Piston Safety Lock

1.
Follow Pressure Relief Procedure, page 18.
2.
Flush Gun, page 23.
3.
Disconnect air (D) and remove fluid manifold (G).
G
4.
Unscrew cap (10) from stop (15), using two pair of
channel-lock pliers. Inspect spring (17), safety
actuator (3), bushing (4), and o-rings (14, 18).
15
18
14
5.
Lubricate o-rings (14, 18) and piston safety lock
actuator (3), and reassemble. Use Fusion Gun
Lubricant 118665. Clean threads with solvent or
alcohol. Apply medium-strength Loctite® or equiv-
alent to threads on stop (15) and cap (10), and
reassemble.
6.
Attach fluid manifold. Connect air. Return gun to
service.
310648E
D
TI4968a
3, 4
10
17
TI3835b

Air Valve

1.
Follow Pressure Relief Procedure, page 18.
2.
Flush Gun, page 23.
3.
Disconnect air (D) and remove fluid manifold (G).
G
4.
Unscrew air valve plug (2) and remove spring (26).
Using small screwdriver (54), push spool (27) out
from front. Inspect o-rings (24).
24
5.
Liberally lubricate o-rings and reassemble. Use
Fusion Gun Lubricant 118665. Torque plug (2) to
125-135 in-lb (14-15 N•m).
6.
Attach fluid manifold. Connect air. Return gun to
service.
Repair
D
TI4968a
2
26
27
TI4990a
41