Auto-Calibrate - SATO CX208 Programming Manual

Desktop printer
Hide thumbs Also See for CX208:
Table of Contents

Advertisement

Command Structure
Command Function
Input to Printer
Printer Output
Special Notes
Page 88

Auto-Calibrate

<ESC>CFa
a
=
0
Disable Auto-Calibrate
1
Enable Auto-Calibrate
Example:
<ESC>CF1
Placement:
This command should be sent in a separate data
stream.
Default:
Enabled
To enable/disable the Auto-Calibrate function.
Theres is no printer output as a result of this command.
1. When Auto-Calibrate is enabled, the printer will automatically
attempt to calibrate when it detects an out-of-paper condition (10"
of platen feed after a label is printed without detecting a label edge
or sense mark). If the calibration is successful, the printer shall
move paper to the next index mark and resume normal
operations. If the calibration is not successful, the printer shall
indicate an out-of-paper condition by a red READY LED. The
printer shall restore the original index circuit settings.
2. See "Label Sensing" on page 8 for more information on
calibration.