Installation
Air and Fluid Hose Kits (F): an 18 in. kit for wall
mounted pumps and a 6 ft kit for drum mounted
pumps are available. Use a minimum 1/4 in. ID air
supply hose between the pump air inlet and the air
accessories. To order a kit with a 1.4 in. air hose, a
1.4 in. swivel elbow, a 3/4 in. fluid hose, and a 3/4
in. swivel elbow, order one of the following kits:
Kit 222118: 18 in. (0.4 m) hose kit for wall mounted
pump
Kit 222119: 6 ft (1.8 m) hose kit for drum mounted
pump
Wall Bracket (J): used for mounting the universal
pump. The wall bracket is sized to fit any Graco
pump designed to use a 2 in. bung adapter (Part
No. 203987).
Runaway Valve (not shown): installation of a
pump runaway valve turns off the air to the pump
when the pump accelerates beyond the
pre-adjusted setting. A pump in a runaway
condition can be seriously damaged.
NOTICE
Do not allow the pump to run dry of the fluid being
pumped. A dry pump quickly accelerates to a high
speed, possibly damaging itself, and it may get very
hot.
Suction Kit (L): enables the pump to draw fluid
from a container. Use with the wall-mounted
universal pump. It includes a drum tube and hose.
Order:
Kit 24F935 - includes 34.8 in. (0.88 m) drum tube
and 78.7 in. (2.0 m) hose
Kit 24H666 - includes 42.1 in. (1.07 m) drum tube
and 78.7 in. (2.0 m) hose
Air Motor Lubricator (D): provides automatic air
motor lubrication. A 300 psi (2.1 MPa, 21 bar) 1/4
npt(f) air motor lubricator is available (Part No.
110148).
Air Regulator and Gauge (C): used to control air
pressure and pump speed. A 0-200 psi (0-1.4 MPa,
0-14 bar) regulated pressure range 300 psi (2.1
MPa, 21 bar) maximum, 1/4 npt(f) air regulator and
gauge are available (Part No.110147).
Air Filter (B): removes harmful dirt and moisture
from the compressed air supply. A 300 psi (2.1
MPa, 21 bar), 1/4 npt(f) 20 micron air filter is
available (Part No. 110146).
6
Air and Fluid Shut Off Valves (A and H):
installation of air shut off valve (A) and fluid shut off
valve (H) isolates the pump while being serviced,
see F
. 1, page 4.
IG
Quick Disconnect Coupler and Nipple (not
shown): used to quickly disconnect the air supply.
Attach coupler (Part No. 208536) to the pump air
inlet hose and install the nipple (Part No. 139970) to
the pump air inlet (p).
Additionally, for permanent installations, a thermal relief
kit is required.
Thermal relief kit (R): assists in relieving pressure
in the pump, hose, and dispensing valve due to
heat expansion (Part No. 237601).

Other Accessories

Extension tubes: pump models 279036 and
279037 have extension tubes. An extension tube
(29, 30) can be added to the universal pump
(279035) to use in submerged applications.
Install extension tube: apply PTFE tape to the
female threads at the top of the tube, then thread
the tube into the intake housing of the universal
pump.