Operating Instructions; Control Panel Features; Operation Instructions - Midea MP05SRWBA3RCM User Manual

Table of Contents

Advertisement

Available languages

Available languages

Operating Instructions

Control Panel Features

NOTE: The following control panels
purchased may be slightly different according to the models. Your machine may not contain some indicators or
buttons. The actual shape shall prevail.
CONSTANT FAN(Press 3s)
VENT CONSTANT(Presse 3s)
MODE button
Selects the appropriate operating mode. Each
CONSTANT FAN(Press 3s)
VENT CONSTANT(Presse 3s)
time you press the button, a mode is selected in a
sequence that goes from COOL, FAN, DRY, HEAT
(on some models), and AUTO(on some models).
The mode indicator light illuminates under the
different mode setting.
NOTE: On above modes, the unit operates the auto
fan speed automatically.
Up (+) and Down (-) buttons
Used to adjust (increasing/decreasing) temperature
settings in 1°C/2°F(or 1°F) increments in a range of
17°C/62°F to 30°C/88°F (or 86°F).
NOTE: The control is capable of displaying
temperature in degrees Fahrenheit or degrees
Celsius. To convert from one to the other, press and
hold the Up and Down buttons at the same time for
3 seconds.
Power button
Power switch on/off.

Operation Instructions

COOL operation
· Press the "MODE" button until the "COOL" indicator
light comes on.
· Press the ADJUST buttons "+" or "-" to select your
Page 18
are for explanation purpose only. The control panel of the unit you
Power
indicator light
Either Timer
or Wireless
indicator light
Timer indicator
light(only set by
remote controller)
Wireless indicator
light(only for the
unit with wireless
controll feature)
· Press the "FAN SPEED" button to choose the
Vent Constant
LED display
Shows the set temperature while on cool,
heat or auto mode. While on DRY and FAN
modes, it shows the room temperature.
Shows Error codes:
E0-EEPROM error.
E1-Room temperature sensor error.
E2-Evaporator temperature sensor error.
E3-Condenser temperature sensor error
(on some models).
E4-Display panel communication error.
EC-Refrigerant leakage detection
malfunction(on some models).
Shows protection code:
P1-Bottom tray is full--Connect the drain
hose and drain the collected water away.
If protection repeats,call for service.
NOTE: When one of the above malfunctions
occurs, turn off the unit, and check for any
obstructions. Restart the unit, if the
malfunction is still present, turn off the unit
and unplug the power cord. Contact the
manufacturer or its service agents or a
similar qualified person for service.
desired room temperature. The temperature can be
set within a range of 17°C~30°C/62°F~88°F(or 86°F).
fanspeed. (on some models)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp07srwba3rcm

Table of Contents