Installing/Removing Line Modules - Siemens RUGGEDCOM RX1511 3 Installation Manual

Table of Contents

Advertisement

Chapter 3
Modules
RUGGEDCOM RX1500PN LM Blank
Section 3.2

Installing/Removing Line Modules

Upon installing a new line module in the device, all features associated with the module are available in
RUGGEDCOM ROX II. For more information, refer to the RUGGEDCOM ROX II User Guide for the RUGGEDCOM
RX1511.
Once a line module is removed, all the features associated with the module are hidden or disabled in RUGGEDCOM
ROX II.
CAUTION!
Electrical hazard – risk of power failure. Do not install more than two RUGGEDCOM APE modules.
Installing more than two of this type of module can lead to power fluctuations and irregular shut
downs.
IMPORTANT!
Only one WAN line module is supported per chassis.
CAUTION!
Contamination hazard – risk of equipment damage. Prevent the ingress of water, dirts and other debris
that may lead to premature equipment failure. Always make sure slots are not left empty and open
ports are protected with plugs or covers.
Removing a Module
To remove a line module, do the following:
1.
Make sure power to the device has been disconnected and wait approximately two minutes for any remaining
energy to dissipate.
2.
[Optional] If the device is installed in a rack, remove it from the rack.
3.
Loosen the screws that secure the module.
4.
Pull the module from the chassis to disconnect it.
26
Specifications
RUGGEDCOM RX1511
Installation Guide
Article Numbers
6GK6015-0AL20-0AA0
(Standard)
6GK6015-0AL20-0AA1
(Conformal Coated)
Installing/Removing Line Modules