DEVELOPMENT OF
TIME-AND-DISTANCE GUIDELINES FOR USE OF
THEATRICAL SMOKE EQUIPMENT:
ROSCO DELTA HAZER
Prepared for:
Rosco Laboratories
Stamford, Connecticut
Prepared by:
ENVIRON International Corporation
Groton, Massachusetts
August 2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Delta Hazer and is the answer not in the manual?

Questions and answers

Summary of Contents for Rosco Delta Hazer

  • Page 1 DEVELOPMENT OF TIME-AND-DISTANCE GUIDELINES FOR USE OF THEATRICAL SMOKE EQUIPMENT: ROSCO DELTA HAZER Prepared for: Rosco Laboratories Stamford, Connecticut Prepared by: ENVIRON International Corporation Groton, Massachusetts August 2006...
  • Page 2: Table Of Contents

    III. RESULTS AND DISCUSSION ...6 Aerosol Monitor Calibration...6 Peak Exposure Characterization ...6 How to Use the Time-and-Distance Guidelines Tables...6 REFERENCES ...9 ROSCO DELTA HAZER C O N T E N T S Page E N V I R O N...
  • Page 3 Rosco Laboratories Delta Hazer ...5 Figure 2: Monitoring configuration ...5 Figure 3: Calibration curve for Delta Hazer Fluid in Rosco Delta Hazer ...8 Table 1: Summary of Time-and-Distance Guidelines for Fog Generation...7 Appendix A: Material Safety Data Sheet ROSCO DELTA HAZER...
  • Page 4: Introduction

    ENVIRON to develop time-and-distance guidelines for the use of the Rosco Delta Hazer. The fluid tested with the Delta Hazer, a glycol-based fluid, was unnamed at the time of the testing, and is referred to in this report as Delta Hazer Fluid.
  • Page 5: Use Of Time-And-Distance Guidelines

    Delta Hazer. Thus, by arranging the blocking and choreography such that an actor is not situated within the restricted areas during the times specified in Table 1, actors should not receive peak exposures above the Guidelines.
  • Page 6: Ii. Testing Methodology

    • The second step involves using the calibrated aerosol monitor to identify distances from the fog release point where exceedances of the guidance levels occur. Testing of the Delta Hazer was conducted at ENVIRON’s testing facility and the Groton Dunstable Middle School Performing Arts Center, both located in Groton, Massachusetts.
  • Page 7 The Delta Hazer was placed on the floor, representative of its typical use in the field. The tripods were placed at various distances from the haze machine release nozzle to achieve a range of exposure concentrations.
  • Page 8 Figure 1. Rosco Laboratories Delta Hazer. Figure 2. Monitoring configuration consisting of six tripod-mounted aerosol monitors situated at three-foot intervals from the Delta Hazer machine. Each tripod is equipped with an aerosol monitor. ROSCO DELTA HAZER E N V I R O N...
  • Page 9: Results And Discussion

    Table 1 has elapsed following the end of the cue. In the case of the Delta Hazer, no exceedances were measured any distance following a 30 to 600 second (10 minute) cue duration, even at the highest fog output setting (99%).
  • Page 10 Delta Hazer without conducting monitoring. However, these Guidelines may not be appropriate for all productions. Table 1 is based on the Delta Hazer being positioned at ground level, and being operated to achieve 30 to 600 seconds of continuous fog generation.
  • Page 11 Ave rage PDR Conce ntration(mg/m Figure 3. Calibration curve for Delta Hazer Fluid in Rosco Delta Hazer. Calibration factor, based on slope of curve, is 0.71 (mg/m ROSCO DELTA HAZER Rosco De lta Haz e r De lta Haz e r Fluid glycols)/ (mg/m aerosol).
  • Page 12: Iv. References

    Issue 1. NIOSH Manual of Analytical Methods (NMAM). Fourth Edition. May 15. Pendergrass, S.M. 1999. Determination of glycols in air: Development of sampling and analytical methodology and application to theatrical smokes. AIHA Journal, 60:452-457. ROSCO DELTA HAZER IV. REFERENCES E N V I R O N...
  • Page 13 APPENDIX A Material Safety Data Sheet E N V I R O N...
  • Page 14: Material Safety Data Sheet

    (203) 708-8900 Eastern Time (323) 462-2233 Pacific Time EMERGENCY For a transport accident or leak, fire or major spill, call CHEMTREC, (24 hrs.) (800) 424-9300 ROSCO DELTA HAZE FLUID Material Name: Read the entire MSDS for a complete hazard assessment. SECTION 2: COMPOSITION/INFORMATION on INGREDIENTS*...
  • Page 15: Section 4: First Aid Measures

    MSDS (continued) Product: ROSCO DELTA HAZE FLUID SECTION 4: FIRST AID MEASURES General First Aid Procedures Eyes Immediately flush with plenty of water for at least 15 minutes. If redness, itching, or a burning sensation develops, have eyes examined and treated by medical personnel.
  • Page 16: Section 6: Accidental Release Measures

    MSDS (continued) Product: ROSCO DELTA HAZE FLUID Page 3 of 7 SECTION 6: ACCIDENTAL RELEASE MEASURES Spill procedures Ventilate spill area. Wear eye, skin and respiratory protection during cleanup. Contain spill. Soak up material with absorbent and shovel into a chemical waste container. Avoid runoff to waterways and sewers.
  • Page 17: Section 9: Physical And Chemical Properties

    MSDS (continued) Product: ROSCO DELTA HAZE FLUID SECTION 9: PHYSICAL and CHEMICAL PROPERTIES Physical State: Liquid Appearance: Clear Odor: None Odor Threshold: No Data Boiling Point: 212-470 Decomposition Temperature: No Data Melting Point: No Data Vapor Pressure (mm Hg at 20 Vapor Density (air = 1): 2.9...
  • Page 18: Section 11: Toxicological Information

    MSDS (continued) Product: ROSCO DELTA HAZE FLUID SECTION 11: TOXICOLOGICAL INFORMATION Routes of Exposure: inhalation, ingestion, eye or skin contact. Eye: Only a slight, transient eye irritant based on ingredients. Mist may cause slight eye irritation. Skin: Not a skin irritant based on ingredients.
  • Page 19: Section 15: Regulatory Information

    MSDS (continued) Product: ROSCO DELTA HAZE FLUID SECTION 15: REGULATORY INFORMATION US Regulations SARA Title III (Emergency Planning and Community Right-To-Know Act) Section 313 Reportable ingredients: This product does not contain any chemicals subject to the reporting requirements of SARA Section 313.
  • Page 20 MSDS (continued) Product: ROSCO DELTA HAZE FLUID We assigned NFPA and HMIS ratings to this product based on the hazards of its ingredient(s). Because the customer is most aware of the application of the product, he must ensure that the proper personal protective equipment (PPE) is provided consistent with information contained in the product MSDS and its use.*...