Page 1
DEVELOPMENT OF TIME-AND-DISTANCE GUIDELINES FOR USE OF THEATRICAL SMOKE EQUIPMENT: ROSCO DELTA 3000 Prepared for: Rosco Laboratories Stamford, Connecticut Prepared by: ENVIRON International Corporation Groton, Massachusetts May 2004...
III. RESULTS AND DISCUSSION ...6 Aerosol Monitor Calibration...6 Peak Exposure Characterization ...6 How to Use the Time-and-Distance Guidelines Tables...7 REFERENCES ...15 ROSCO DELTA 3000 C O N T E N T S Page E N V I R O N...
Page 3
Guidelines for use of Rosco Clear Fog Fluid in Delta 3000 fog machine...11 Figure 8: Guidelines for use of Rosco Light Fog Fluid in Delta 3000 fog machine ...12 Figure 9: Guidelines for use of Rosco Fog Fluid in Delta 3000 fog machine...13...
Rosco Laboratories (Rosco) retained ENVIRON to develop time-and-distance guidelines for the use of the Rosco Delta 3000 fog machine (Figure 1). ROSCO DELTA 3000 I.
Delta 3000 fog machine. Thus, by arranging the blocking and choreography such that an actor is not situated within the restricted areas during the times specified in Table 2 and Figures 7 to 10, actors should not receive peak exposures.
The six tripods were placed at distances ranging from 5 to 30 feet from the Delta 3000 release point for the 100% and 50% settings, and at distances ranging from 3 to 18 feet for the 10% setting. The Delta 3000 was turned on for 30 to 60 seconds, allowing sustained smoke generation to occur, and then turned off.
Figure 2. Monitoring configuration consisting of six tripod-mounted aerosol monitors situated at five foot intervals from the Delta 3000 machine (far left). Each tripod is equipped with an aerosol monitor. ROSCO DELTA 3000 E N V I R O N...
For 100% and 50% settings, monitoring data collected using aerosol monitors placed at distances of 5, 10, 15, 20, 25, and 30 feet from the Delta 3000 machine were combined with the calibration factors to determine the levels of smoke at different distances from the release point and times following the release.
Table 2 has elapsed following the end of the cue. For example, if a production is using the Delta 3000 at a 50% setting with Stage & Studio fluid, an actor should not be situated within five feet from the front of the cue release point until at least 50 seconds following the end of the cue release;...
Figure 3. Calibration curve for Rosco Clear Fog Fluid in Delta 3000. Calibration factor, based on slope of curve, is 1.43 (mg/m Figure 4. Calibration curve for Rosco Light Fog Fluid in Delta 3000. Calibration factor, based on slope of curve, is 1.35 (mg/m...
Figure 5. Calibration curve for Rosco Fog Fluid in Delta 3000. Calibration factor, based on slope of curve, is 1.00 (mg/m Figure 6. Calibration curve for Rosco Stage & Studio Fluid in Delta 3000. Calibration factor, based on slope of curve, is 1.97 (mg/m...
Figure 7. Guidelines for use of Rosco Clear Fog Fluid in Delta 3000 fog machine ROSCO DELTA 3000 Clear Fog Fluid Distance (ft) 100% (30-second release) 50% (30-second release) 10% (60-second release) -11- E N V I R O N...
Figure 8. Guidelines for use of Rosco Light Fog Fluid in Delta 3000 fog machine ROSCO DELTA 3000 Light Fog Fluid Distance (ft) 100% (30-second release) 50% (30-second release) 10% (60-second release) -12- E N V I R O N...
Figure 9. Guidelines for use of Rosco Fog Fluid in Delta 3000 fog machine ROSCO DELTA 3000 Rosco Fog Fluid Distance (ft) 100% (30-second release) 50% (30-second release) 10% (60-second release) -13- E N V I R O N...
Figure 10. Guidelines for use of Rosco Stage and Studio Fog Fluid in Delta 3000 fog machine ROSCO DELTA 3000 Stage & Studio Fluid Distance (ft) 100% (30-second release) 50% (30-second release) 10% (60-second release) -14- E N V I R O N...
Mount Sinai School of Medicine and ENVIRON International Corporation (Mt. Sinai and ENVIRON). 2000. Health effects evaluation of theatrical smoke, haze, and pyrotechnics. Prepared for Equity-League Pension and Health Trust Funds. June 6. ROSCO DELTA 3000 IV. REFERENCES -15- E N V I R O N...
Page 19
= adjustment factor (unitless) = release duration (sec) For using the Rosco Delta 3000 at release durations that differ from those on which the T&D Guideline report was based, the T&D guideline value from Table 2 can be multiplied by the 274 Main Street C P.O.
Page 20
Therefore, the T&D value would be 94 seconds × 0.79 or 74 SECONDS. 2. Using Rosco Clear Fog Fluid with the Delta 3000 at a 10% setting, Table 2 from the T&D Guideline report gives a value of 130 SECONDS at 6 feet from the release point. For a release duration of 30 seconds, the adjustment factor is: AF = (0.93...
Page 21
Eric Tishman June 22, 2004 Figure 1. Percent change in T&D guidance value from 30-second value for 50% and 100% settings at release durations other than 30 seconds. Figure 2. Percent change in T&D guidance value from 60-second value for 10% setting at release durations other than 60 seconds.
Need help?
Do you have a question about the Delta 3000 and is the answer not in the manual?
Questions and answers