Fibre Channel Zoning - HP P6300 Enterprise Virtual Array Installation Manual

Table of Contents

Advertisement

show feature_keys
show initiators [ fc | iscsi ]
show iscsi [ <PORT_NUM> ]
show isns
show logs [ <ENTRIES> ]
show luninfo
show luns
show memory
show mgmt
show ntp
show perf [ byte | init_rbyte | init_wbyte | tgt_rbyte | tgt_wbyte ]
show presented_initiators [ fc | iscsi ]
show presented_targets [ fc | iscsi ]
show properties
show rpcinfo
show snmp
show stats
show system
show targets [ fc | iscsi ]
show vpgroups [vpgroup index]
shutdown
target [ add | rm ]
targetmap [ add | rm ]
traceroute
iSCSI Server Connectivity Command Set:
========================================
lunmask [ add | rm ]
show [initiators_lunmask | lunmask ]
show initiators_lunmask
show lunmask
Once you have established initial connectivity with the iSCSI or iSCSI/FCoE module management
ports, HP recommends that you verify the iSCSI or iSCSI/FCoE modules are in a defined state
(before using HP P6000 Command View and beginning a new configuration). To do this, use the
iSCSI and iSCSI/FCoE CLI to reset default factory settings or mappings. This will clear IP addresses
that were set and requires a reboot. The following is an example of resetting factory settings and
mappings on the iSCSI module:
CLI example of: login
MEZ50 login: guest
Password:
password
Welcome to MEZ50
******************************************************
*
*
*
******************************************************
MEZ50 #> admin start
MEZ50
#> reset factory
Are you sure you want to restore to factory default settings (y/n):
Please reboot the System for the settings to take affect.
MEZ50 #> reboot
Are you sure you want to reboot the System (y/n):
System will now be rebooted...
Note: The CLI reset factory operation returns the management port IP address to the DHCP mode and
clears all other persistent settings.
Or
MEZ50 (admin) #> reset mappings
Are you sure you want to reset the mappings in the system (y/n):
Please reboot the System for the settings to take affect.
MEZ50 (admin) #> reboot
Are you sure you want to reboot the System (y/n):
System will now be rebooted...
Note: The CLI reset mappings operation only clears user defined LUN mappings, and does not alter
other persistent data such as IP addresses.

Fibre Channel zoning

The iSCSI and iSCSI/FCoE modules are directly attached to the array controllers through Fibre
Channel ports
zoning requirements for iSCSI connectivity to the P6300/P6500 EVA. HP P6000 Command View
instantiates host objects which contain Fibre Channel ports, with consideration of multipath LUN
All manuals and user guides at all-guides.com
reset [ factory | mappings ]
reboot
HP StorageWorks MEZ50
p config
(Figure 22 (page 38)
and
y
y
y
Figure 23 (page
38)), therefore, there are no Fibre Channel
*
*
*
y
Fibre Channel zoning
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

P6500 enterprise virtual array

Table of Contents