Toshiba B-FP Series Manual page 8

Table of Contents

Advertisement

[Adjustment] Group
[Feed Position]
Sets a fine adjustment value for the stop position in units of 0.1 mm.
When the value is negative (-), the feed length to the stop position becomes longer.
When the parameter is not retrieved, the PC value set by the Position Fine Adjust command [AX]
becomes zero (0).
Default
Range
[X-coordinate]
Sets a fine adjustment value to offset the print position perpendicular to the paper feed direction in
units of 0.1 mm.
When the value is negative (-), the origin coordinate at the upper left is moved to the left from the
zero position.
Default
Range
[Tone Adjust]
Sets a fine adjustment value for print density in the direct thermal print mode.
When the parameter is not retrieved, the PC value set by the Print Density Fine Adjust command
[AY] becomes zero (0).
Default
Range
[Peel-off Position]
Sets a fine adjustment value for a strip position in units of 0.1 mm.
When the value is negative (-), the feed length to the strip position becomes longer.
When the parameter is not retrieved, the PC value set by the Position Fine Adjust command [AX]
becomes zero (0).
Default
Range
[ESC/POS Width]
Sets the label width loaded on the printer in units of 1 mm.
This is available only for the ESC/POS mode.
Default
Range
[Sensor] group
[Reflective Sensor Threshold]
Sets a fine adjustment value for the threshold to the reflective sensor output in units of 0.1 V.
Default
Range
[Transmissive Sensor Threshold]
Sets a fine adjustment value for the threshold to the transmissive sensor output in units of 0.1 V.
Default
Range
+00.0 (mm)
-50.0 to +50.0 (mm)
+00.0 (mm)
-99.9 to +99.9 (mm)
+00
-30 to +30
+00.0 (mm)
-02.0 to +03.0 (mm)
058.0 (mm)
025.0 to 058.0 (mm)
1.0 (V)
0.0 to 4.0 (V)
1.4 (V)
0.0 to 4.0 (V)
6