Field Settings Table - Daikin ERLA03DAV3 Installer's Reference Manual

Hide thumbs Also See for ERLA03DAV3:
Table of Contents

Advertisement

2/7

Field settings table

Breadcrumb
Field code
Setting name
User settings
└─ Preset values
└─ Room temperature
7.4.1.1
Comfort (heating)
7.4.1.2
Eco (heating)
7.4.1.3
Comfort (*)
7.4.1.4
Eco (*)
└─ LWT main
7.4.2.1
[8-09]
Comfort (heating)
7.4.2.2
[8-0A]
Eco (heating)
7.4.2.3
[8-07]
Comfort (*)
7.4.2.4
[8-08]
Eco (*)
└─ Tank temperature
7.4.3.1
[6-0A]
Storage comfort
7.4.3.2
[6-0B]
Storage eco
7.4.3.3
[6-0C]
Reheat
└─ Quiet level
7.4.4
└─ Set weather dependent
└─ Main
└────────────────── Set weather-dependent heating
7.7.1.1
[1-00]
Set weather-dependent heating
7.7.1.1
[1-01]
Set weather-dependent heating
7.7.1.1
[1-02]
Set weather-dependent heating
7.7.1.1
[1-03]
Set weather-dependent heating
└────────────────── Set weather-dependent Cooling
7.7.1.2
[1-06]
Set weather-dependent Cooling
(*)
7.7.1.2
[1-07]
Set weather-dependent Cooling
(*)
7.7.1.2
[1-08]
Set weather-dependent Cooling
(*)
7.7.1.2
[1-09]
Set weather-dependent Cooling
(*)
└─ Additional
└────────────────── Set weather-dependent heating
7.7.2.1
[0-03]
Set weather-dependent heating
7.7.2.1
[0-02]
Set weather-dependent heating
7.7.2.1
[0-01]
Set weather-dependent heating
7.7.2.1
[0-00]
Set weather-dependent heating
└────────────────── Set weather-dependent Cooling
7.7.2.2
[0-07]
Set weather-dependent Cooling
(*)
7.7.2.2
[0-06]
Set weather-dependent Cooling
(*)
7.7.2.2
[0-05]
Set weather-dependent Cooling
(*)
7.7.2.2
[0-04]
Set weather-dependent Cooling
(*)
Installer settings
└─ System layout
└─ Standard
A.2.1.1
[E-00]
Unit type
A.2.1.2
[E-01]
Compressor type
A.2.1.3
[E-02]
Indoor software type
A.2.1.7
[C-07]
Unit control method
A.2.1.9
[F-0D]
Pump operation mode
A.2.1.A
[E-04]
Power saving possible
A.2.1.B
User interface location
└─ Options
A.2.2.1
[E-05]
DHW operation
A.2.2.3
[E-07]
DHW tank type
A.2.2.4
[C-05]
Thermostat Type
A.2.2.A
[D-02]
Which type of DHW pump is installed?
A.2.2.B
[C-08]
External sensor
A.2.2.G
LAN Adapter
└─ Space operation
└─ LWT settings
└────────────────── Main
4P596829-1 - 2019.10
Low ambient temp. for LWT main zone heating
WD curve.
High ambient temp. for LWT main zone heating
WD curve.
Leaving water value for low ambient temp. for
LWT main zone heating WD curve.
Leaving water value for high ambient temp. for
LWT main zone heating WD curve.
'Low ambient temp. for LWT main zone cooling
WD curve.
High ambient temp. for LWT main zone cooling
WD curve.
'Leaving water value for low ambient temp. for
LWT main zone cooling WD curve.
'Leaving water value for high ambient temp. for
LWT main zone cooling WD curve.
Low ambient temp. for LWT add zone heating
WD curve.
High ambient temp. for LWT add zone heating
WD curve.
Leaving water value for low ambient temp. for
LWT add zone heating WD curve.
Leaving water value for high ambient temp. for
LWT add zone heating WD curve.
Low ambient temp. for LWT add zone cooling
WD curve.
High ambient temp. for LWT add zone cooling
WD curve.
Leaving water value for low ambient temp. for
LWT add zone cooling WD curve.
Leaving water value for high ambient temp. for
LWT add zone cooling WD curve.
(*) Setting is not applicable for this unit
Range, step
Default value
R/W
[3-07]~[3-06], step: A.3.2.4
22°C
R/W
[3-07]~[3-06], step: A.3.2.4
18°C
R/W
[3-09]~[3-08], step: A.3.2.4
24°C
R/W
[3-09]~[3-08], step: A.3.2.4
28°C
R/W
[9-01]~[9-00], step: 1°C
35°C
R/W
[9-01]~[9-00], step: 1°C
33°C
R/W
[9-03]~[9-02], step: 1°C
18°C
R/W
[9-03]~[9-02], step: 1°C
20°C
R/W
30~[6-0E]°C, step: 1°C
60°C
R/W
30~min(50, [6-0E])°C, step: 1°C
50°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
1: Level 1
2: Level 2
3: Level 3
R/W
-40~5°C, step: 1°C
-10°C
R/W
10~25°C, step: 1°C
15°C
R/W
[9-01]~[9-00], step: 1°C
35°C
R/W
[9-01]~min(45, [9-00])°C , step: 1°C
25°C
R/W
10~25°C, step: 1°C
20°C
R/W
25~43°C, step: 1°C
35°C
R/W
[9-03]~[9-02]°C, step: 1°C
22°C
R/W
[9-03]~[9-02]°C, step: 1°C
18°C
R/W
-40~5°C, step: 1°C
-10°C
R/W
10~25°C, step: 1°C
15°C
R/W
[9-05]~[9-06]°C, step: 1°C
50°C
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
R/W
10~25°C, step: 1°C
20°C
R/W
25~43°C, step: 1°C
35°C
R/W
[9-07]~[9-08]°C, step: 1°C
12°C
R/W
[9-07]~[9-08]°C, step: 1°C
8°C
R/O
0~5
0: LT split
R/O
0
R/O
1
R/W
0: LWT control
1: Ext RT control
2: RT control
R/W
0: Continuous
1: Sample
2: Request
R/O
1: Yes
R/W
0: At unit
1: In room
R/O
0~1
1. Yes
R/O
0~6
1: Integrated
R/W
0: -
1: 1 contact
2: 2 contacts
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/W
0: No
1: Yes
Installer setting at variance with
default value