ERLA03DAV3 + EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1A – 2020.05
#
Code
N/A
[9‑0E]
N/A
[9‑0D]
The maximum values depend on the unit type:
[9-0D]=0
a (kPa)
b (l/min)
[9-0D]=6
a (kPa)
Pump speed limitation main zone
▪
0: No limitation.
▪
1~4: General limitation. There is limitation in all
conditions. The required delta T control and
comfort are NOT guaranteed.
▪
5~8 (default: 6): Limitation when no actuators.
When there is no heating output, the pump
speed limitation is applicable. When there is
heating output, the pump speed is only
determined by delta T in relation to the
required capacity. With this limitation range,
delta T is possible and the comfort is
guaranteed.
Pump speed limitation additional zone
▪
0: No limitation.
▪
1~4: General limitation. There is limitation in all
conditions. The required delta T control and
comfort are NOT guaranteed.
▪
5~8 (default: 6): Limitation when no actuators.
When there is no heating output, the pump
speed limitation is applicable. When there is
heating output, the pump speed is only
determined by delta T in relation to the
required capacity. With this limitation range,
delta T is possible and the comfort is
guaranteed.
[9-0D]=5
a (kPa)
[9-0D]=7
a (kPa)
b (l/min)
9
Configuration
|
Description
b (l/min)
b (l/min)
Installer reference guide