Setting The Temperature Unit ºf ºc; Restoring Factory Settings - Viessmann VITOCROSSAL 300 CU3A 35 Operating Instructions Manual

Floor mounted, gas-fired condensing boiler with matrix gas burner and lambda pro control, for operation with natural gas and liquid propane gas, heating input 19 to 199 mbh, 5.6 to 58 kw, with vitotronic 200 kw6b controls
Hide thumbs Also See for VITOCROSSAL 300 CU3A 35:
Table of Contents

Advertisement

Vitocrossal 300 CU3A 26 to 199 Operating
Setting the Temperature Unit °F (°C)

Restoring Factory Settings

System setting
"Heating circuit 1", "Heating circuit
2" or "Heating circuit 3"
Factory setting: °C
Extended menu:
1.
2. "Settings"
3. "Temperature unit"
4. Select the temperature unit "°C" or "°F".
You can reset the factory settings of all modified values
for each heating circuit separately.
Extended menu:
1.
2. "Settings"
3. "Standard setting"
4. "Heating circuit 1", "Heating circuit 2" or
"Heating circuit 3"
Settings and values that are reset
H Set room temperature: 68°F (20°C)
H Set reduced room temperature
H Operating program
H Set DHW temperature
H Time program for central heating
H Time program for DHW heating
H Time program for DHW recirculation pump
H Heating curve slope and shift
H Comfort and energy saving functions ("Party mode",
"Economy mode", "Holiday program") are deleted.
Note: If heating circuits have been named (see chapter
"Naming heating circuits") the assigned name is
retained.
Additional Adjustments