How To Call; Service Inspection List - Mitsubishi Electric JT-MC106G-W-NA Handbook

Hide thumbs Also See for JT-MC106G-W-NA:
Table of Contents

Advertisement

10. How to call

1 The hand dryer does
not blow air even
though hands are
inserted.
(It may not stop
blowing air in the
cases of 4 and 5.)
2 The hand dryer does
not blow warm air.
3 Air blow is too weak to dry hands quickly.
4 Water leaks from the product.

11. Service inspection list

Location
Electric wiring
Operation
Indicator lights
Drain tank, filter
Wall installation
Symptom
The power light is not
turned on.
Cases other than the
above
The heater light is
not turned on.
Ambient temperature
is low.
Are lead wire connectors connected securely?
Is the wiring correct?
Does the hand dryer operate properly?
Isn't there any abnormal noise, vibration, etc.?
Do the lights (LEDs) come on?
Are the drain tank and filter inserted into the proper position?
Isn't there any gaps between the product and the back wall?
1 If the power wires are disconnected, securely connect
them to the terminal block.
2 If the power is OFF, turn it ON.
3 If the circuit breaker is OFF, turn it ON.
4 The sensor area may get dirt, clean up the sensor area.
5 If some objects are left in the water receiver area, remove
them.
1 If the heater switch is OFF, turn it ON.
2 When the room temperature is 18°C or lower, the hand
dryer, which is equipped with the simple heater, does not
blow sufficiently warm air.
If the filter is clogged, clean it up.
1 If the drain tank is filled with water, empty the tank.
2 If the drain tank is not properly installed, install it properly.
Inspection Item
─ 15 ─
Remedy
Check Result

Advertisement

Table of Contents
loading

Table of Contents