Troubleshooting - Graco 210ES Repair Manual

Electric airless sprayer
Hide thumbs Also See for 210ES:
Table of Contents

Advertisement

Troubleshooting

Problem
Motor Won't Operate
Basic Fluid Pressure
Basic Mechanical
8
What To Check
(If check is OK, go to next check)
1. Pressure control knob setting.
Motor will not run if set at mini-
mum (fully counter-clockwise).
2. Spray tip or fluid filter may be
clogged.
1. Pump frozen or hardened paint
2. Displacement pump connecting
rod pin. Pin must be completely
pushed into connecting rod and
retaining spring must be firmly in
groove or pump pin.
3. Motor. Remove drive housing
assembly. See page 14, Drive
Housing Replacement. Try to
rotate fan by hand.
What To Do
(When check is not OK, refer to this column)
Slowly increase pressure setting to see if motor
starts.
Relieve pressure, page 6. Then clear clog or
clean gun filter. Refer to gun instruction manual,
311979.
Thaw sprayer if water or water-based paint has
frozen in sprayer. Place sprayer in warm area to
thaw. Do not start sprayer until thawed com-
pletely. If paint hardened (dried) in sprayer,
replace pump packings. See page 12, Dis-
placement Pump Replacement.
Push pin into place and secure with spring
retainer. See page 12, Displacement Pump
Replacement.
Replace motor if fan won't turn. See page 26,
Motor Replacement.
Troubleshooting
311990B

Advertisement

Table of Contents
loading

This manual is also suitable for:

190es261825261830

Table of Contents