Graco 261825 Operation Manual

Graco 261825 Operation Manual

Electric airless sprayer
Hide thumbs Also See for 261825:

Advertisement

Operation
190
/210
ES
ES
Pulvérisateurs électriques Airless 190
Pulverizadores eléctricos sin aire 190
- For portable spray application of architectural paints and coatings -
- Pour l'application de peintures et revêtements architecturaux avec un appreil mobile -
- Para aplicaciones de pulverización portátiles de pinturas y revestimientos con fines arquitectónicos -
190
Model: 261825 / 210
ES
Maximum Working Pressure: 3000 psi (20.7 MPa, 207 bar)
Important Safety Instructions
Read all warnings and instructions in
this manual. Save these instructions.
Related Manuals
311990
312830
312831
English
Français
312015
C.J. Spray, Inc.
6270 Claude Way E
Inver Grove Heights, MN 55076
1-888-CJSPRAY
(888-257-7729)
Electric Airless Sprayer
Model: 261830
ES
Instructions de sécurité importantes
Lire toutes les mises en garde et instructions
de ce manuel. Sauvegarder ces intructions.
312832
Español
/210
ES
ES
/210
ES
ES
Instrucciones importantes de seguridad
lea todas las advertencias e instrucciones
de este manual. Guarde las instructionnes.
TM
311988C
ENG FRA SPA
ti16975a

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 261825 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Graco 261825

  • Page 1 - Pour l’application de peintures et revêtements architecturaux avec un appreil mobile - - Para aplicaciones de pulverización portátiles de pinturas y revestimientos con fines arquitectónicos - Model: 261825 / 210 Model: 261830 Maximum Working Pressure: 3000 psi (20.7 MPa, 207 bar) Important Safety Instructions Instructions de sécurité...
  • Page 2 Warning Warning The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.
  • Page 3 Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine Graco replacement parts only. • Do not alter or modify equipment.
  • Page 4 Mise en garde Mise en garde Les mises en gardes suivantes sont des mises en garde de sécurité relatives à la configuration, utilisation, mise à la terre, maintenance et réparation de ce matériel. D’autres mises en garde plus spécifiques figurent dans ce manuel aux endroits concernés.
  • Page 5 à votre distributeur ou revendeur. • Vérifier l’équipement tous les jours. Réparer ou remplacer immédiatement les pièces usées ou endommagées par des pièces de rechange d’origine Graco. • Ne pas modifier cet équipement.
  • Page 6 Advertencias Advertencias A continuación se ofrecen advertencias en general relacionadas con la seguridad de la puesta en marcha, utilización, conexión a tierra, mantenimiento y reparación de este equipo. Además, puede encontrar advertencias adicionales a lo largo de este manual siempre que sea pertinente. Los símbolos que aparecen en el texto del manual se refieren a estas advertencias generales.
  • Page 7 MSDS al distribuidor o al minorista. • Revise el equipo a diario. Repare o cambie inmediatamente las piezas desgastadas o deterioradas únicamente con piezas de repuesto genuinas de Graco. • No altere ni modifique el equipo.
  • Page 8 Component Identification / Identification des composants / Identificación de los componentes Component Identification / Identification des composants / Identificación de los componentes ti9033a ti9034a English Français Español Pressure Control Régulation Control de la presión de pression ON/OFF switch Bouton MARCHE/ARRÊT Interruptor de encendido/apagado Power Cord Cordon électrique...
  • Page 9 Pressure Relief Procedure / Procédure de décompression / Procedimiento de descompresión Pressure Relief Procedure / Procédure de décompression / Procedimiento de descompresión English Français Español Follow this Pressure Relief Procedure whenever you Observer cette Procédure de décompression, à Siga el Procedimiento de descompresión, cuando stop spraying and before cleaning, checking, servic- chaque arrêt de la pulvérisation et avant tout nettoy- deje de pulverizar y antes de limpiar, revisar, reparar...
  • Page 10 Grounding / Mise à la terre / Conexión a tierra Grounding / Mise à la terre / Conexión a tierra English Français Español The sprayer must be grounded. Grounding Ce pulvérisateur doit être raccordé à la terre. Este pulverizador debe estar conectado a tier- reduces the risk of static and electric shock La mise à...
  • Page 11 Grounding / Mise à la terre / Conexión a tierra ground 120 volt plug English Power Requirements Extension Cords • 120V units require • Use an extension cord with an • If an extension cord is necessary, 100 - 120 Vac, 60 Hz, 11A, 1 undamaged ground contact.
  • Page 12 Grounding / Mise à la terre / Conexión a tierra ti5850a ti5851a ti9035a English Pails • Solvent and oil/based fluids: • Do not place pail on a nonconduc- • Grounding a metal pail: connect a • To maintain grounding con- follow local code.
  • Page 13: Setup / Installation / Configuración

    Setup / Installation / Configuración Setup / Installation / Configuración ti9036a ti9037a ti9038a ti9039a English Connect Graco airless hose Connect other end of hose Tighten securely. Remove tip guard. to sprayer. to gun. Tighten securely. Français Brancher un flexible Graco Brancher l’autre extrémité...
  • Page 14 Setup / Installation / Configuración ti5316b ti5301a ti9040a English Check inlet strainer for clogs Fill throat packing nut with Turn power OFF. Plug power supply cord and debris. TSL to prevent premature into a properly grounded packing wear. electrical outlet. Do this each time you spray.
  • Page 15 Setup / Installation / Configuración Flush ti8326a ti9041a English Turn prime valve down. Place siphon tube set in grounded metal pail partially filled with flushing fluid. See Grounding, page 10. Do steps 1- 6 of Startup, page 16, to flush out storage oil shipped in sprayer. Use water to flush water-based paint or mineral spirits to flush oil-based paint and storage oil.
  • Page 16: Startup / Démarrage / Puesta En Marcha

    Startup / Démarrage / Puesta en marcha Startup / Démarrage / Puesta en marcha 1/4 turn ti5303b ti8327a ti8324a ti8325a English Turn pressure control to Turn power ON. Increase pressure 1/4 turn Turn prime valve horizon- lowest pressure. to start motor. Allow fluid tal.Take spray gun trigger to circulate through drain safety OFF.
  • Page 17 Startup / Démarrage / Puesta en marcha Flush Paint Flush ti9035a ti9042a ti9043a English Hold gun against grounded Inspect for leaks. Do not stop Place siphon tube in paint Trigger gun again into metal flushing pail. Trigger leaks with hand or a rag! If pail.
  • Page 18 Startup / Démarrage / Puesta en marcha ti9044a ti9045a English Move gun to paint pail and Screw tip assembly onto trigger for 20 seconds. Set gun. Tighten. For gun gun safety ON. assembly instructions, see gun manual, 311979. Français Déplacer le pistolet vers Visser la buse sur le pistolet.
  • Page 19 Startup / Démarrage / Puesta en marcha Spray Test Pattern / Faire un essai de pulvérisation / Pulverice la plantilla de prueba Heavy Edges ti2758a ti2757a English Spray test pattern. Adjust Use smaller tip size if pres- Hold gun perpendicular, Move gun before triggering.
  • Page 20 Startup / Démarrage / Puesta en marcha Clearing Clogs / Débouchage / Eliminación de las obstrucciones ti9046a ti9048a ti9047a ti9046a titi9049a ti9047a English Release trigger, put safety ON. Rotate Spray Tip. Take safety OFF. Put safety ON. Return Spray Tip to original position. Take safety Trigger gun to clear clog.
  • Page 21: Cleanup / Nettoyage / Limpieza

    Cleanup / Nettoyage / Limpieza Cleanup / Nettoyage / Limpieza Flush Waste ti9039a ti9052a ti9050a Pail Flush English Relieve Pressure, Remove guard and Spray Remove siphon tube set Place siphon tube in flushing page 9. Tip. For additional informa- from paint. Wipe excess fluid.
  • Page 22 Cleanup / Nettoyage / Limpieza ti9044a 1/4 Turn ti8327a ti8326a Waste ti8325a ti9051a English Turn prime valve horizontal. Hold gun against paint pail. Stop triggering gun. Move While continuing to trigger Take trigger safety OFF. gun to waste pail, hold gun gun, turn prime valve down.
  • Page 23 Cleanup / Nettoyage / Limpieza ti8324a ti8327a ti9043a Flush ti9053a ti9052a ti4296a English Raise siphon tube above Close drain valve. Trigger gun Turn pressure control knob Remove filter. Clean flushing fluid. into flushing pail to purge fluid all the way down and power and inspect.
  • Page 24 Cleanup / Nettoyage / Limpieza Pump Armor ti2783a ti2895a English Remove filter from gun if If flushing with water, flush Wipe sprayer, hose and gun installed. Clean and again with mineral spirits or with a rag soaked in water inspect. Install filter. See Pump Armor to leave a pro- or mineral spirits.
  • Page 25 Cleanup / Nettoyage / Limpieza ti9052a ti9039a ™ English Power Flush Power flushing is a faster Relieve Pressure, Remove guard and spray Remove siphon tube set method of flushing. It can only be page 9. tip. For additional from paint. Wipe excess used after spraying water-based information, see gun paint off outside of tubes.
  • Page 26 Cleanup / Nettoyage / Limpieza ti9412a ti9429a ti9413a ti9414a English Unscrew inlet strainer from Screw shutoff valve onto Turn on water. Rinse paint Connect power flush suction tube. Place inlet garden hose. Turn lever and off suction tube, prime tube adapter to suction tube.
  • Page 27 Cleanup / Nettoyage / Limpieza 1/4 turn ti8327a ti9415a ti8325a English Turn Spray-Prime/Drain Open lever on shutoff valve. Turn Pressure Control knob Step 11 is for returning paint in valve to SPRAY. 1/4 turn clockwise. hose back to paint pail. One 50-ft (15-m) hose holds approximately 1-quart (1-liter) of paint.
  • Page 28 Cleanup / Nettoyage / Limpieza ti5303b ti9044a ti8326a ti9043a ti9050a English Remove paint from hose. Continue triggering gun into Turn Spray-Prime/Drain Circulate water through waste pail for 1-2 minutes, valve to PRIME. sprayer, into waste pail, for Pull and hold gun trig- until relatively clear water 20 seconds.
  • Page 29 Cleanup / Nettoyage / Limpieza ti8327a ti5316b ti5316b ti5303b ti8324a Flush ti9043a ti4296a ti9416a ti9417a English Turn power switch OFF. Unscrew shutoff valve from Close drain valve. Turn Turn pressure control knob Close shutoff valve. Turn off garden hose. Remove power ON.
  • Page 30 Cleanup / Nettoyage / Limpieza Pump Armor ti2783a ti2895a ti9053a English Remove filter. Clean and Remove filter from gun if If flushing with water, flush Wipe sprayer, hose and gun inspect. Install filter. installed. Clean and again with mineral spirits or with a rag soaked in water inspect.
  • Page 31: Technical Data

    Technical Data Technical Data Power requirements ......120 Vac, 60 Hz, 11A, 1 phase Generator required .
  • Page 32: Características Técnicas

    Características técnicas Características técnicas Requisitos eléctricos ......120V CA, 60 Hz, 11A, monofásico Generador necesario .
  • Page 33: Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.
  • Page 34 Warranty TO PLACE AN ORDER, contact your Graco distributor, or call 1-800-690-2894 to identify the nearest distributor. All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice.
  • Page 35 ™ /210 Electric Airless Sprayer 311990H - For portable spray application of architectural paints and coatings - Model: 261825 Model: 261830 Maximum Working Pressure: 3000 psi (20.7 MPa, 207 bar) Important Safety Instructions Read all warnings and instructions in this manual.
  • Page 36 Warning Warning The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where appli- cable.
  • Page 37 Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine Graco replacement parts only. • Do not alter or modify equipment.
  • Page 38: Component Identification

    Component Identification Component Identification ti9033a Component Pressure Control ON/OFF Switch Power Cord Fluid Outlet Prime Valve Kick Stand (210 Series A) Pump Suction Tube Drain Hose Fluid Hose Guard Trigger Safety Lock Serial Number ID Label Filter Cap Pail Hook Power Flush Adapter Shutoff Valve 311990H...
  • Page 39: Installation

    Installation Installation Grounding and Electric Do not use the sprayer if the electrical cord has a dam- aged ground contact. Only use an extension cord with Requirements an undamaged ground contact. The sprayer cord includes a grounding wire with an appropriate grounding contact.
  • Page 40: Pressure Relief Procedure

    Pressure Relief Procedure Pressure Relief Procedure 3. Turn prime valve down. Follow this Pressure Relief Procedure whenever you are instructed to relieve pressure, stop spraying, check or service equipment or install or clean spray tip. ti8326a 1. Turn OFF power and turn pressure control to lowest pressure setting.
  • Page 41: General Repair Information

    General Repair Information General Repair Information To reduce risk of serious injury, including electric shock: • Do not touch moving or electric parts with fingers or tools while testing repair. • Unplug sprayer when power is not required for Flammable materials spilled on hot, bare, motor testing.
  • Page 42: Troubleshooting

    Troubleshooting Troubleshooting What To Check What To Do Problem (If check is OK, go to next check) (When check is not OK, refer to this column) Motor Won’t Operate Basic Fluid Pressure 1. Pressure control knob setting. Slowly increase pressure setting to see if Motor will not run if set at mini- motor starts.
  • Page 43 Troubleshooting What To Check What To Do Problem (If check is OK, go to next check) (When check is not OK, refer to this column) Basic Electrical 1. Electric supply. ON/OFF switch in Turn ON/OFF switch to ON position. Reset See wiring diagram, page OFF position.
  • Page 44 Troubleshooting What To Check What To Do Problem (If check is OK, go to next check) (When check is not OK, refer to this column) Low Output 1. Worn spray tip. Relieve pressure, page 6. Replace tip. Refer to gun instruction manual, 311979. 2.
  • Page 45 Troubleshooting What To Check What To Do Problem (If check is OK, go to next check) (When check is not OK, refer to this column) Motor runs and pump 1. Prime Valve Open. Close prime valve. strokes 2. Paint supply. Refill and reprime pump.
  • Page 46: Displacement Pump Replacement

    Displacement Pump Replacement Displacement Pump Replacement See manual 312015 for pump repair instructions. 4. Cycle pump until pin (31) is in position to be removed. Removal 5. Disconnect power cord from outlet. 6. Push up retaining spring (C). Push out pump pin (31). 1.
  • Page 47 3. Install pump pin (31). Verify retainer spring (30a) is in groove over pump pin. ti9139a 9. Fill packing nut with Graco TSL until fluid flows onto top of seal. Install pail hanger (10) with screws (11). ti9144a 4. Push pump (33) up until pump threads engage.
  • Page 48: Drive Housing Replacement

    Drive Housing Replacement Drive Housing Replacement Installation 1. Apply a liberal coat of grease to gears and needle bearing surfaces. Install thrust bearing (28) and gears (26) and (27) in motor front endbell. Removal 1. Relieve pressure, page 6. 2. Remove pump (33). Displacement Pump Replace- ment, page 12.
  • Page 49: Spin Test

    Spin Test Spin Test Armature, Brushes, and Motor Wiring Open See Wiring Diagram, page 27. Circuit Test (Continuity) 1. Connect red and black motor leads with test lead. Turn motor fan by hand at about two revolutions per second. To check armature, motor winding and brush electrical 2.
  • Page 50: Fan Replacement

    Fan Replacement Fan Replacement Removal Installation 1. Slide new fan (57a) on back of motor. Be sure fan blades face motor. 2. Install spring clip (57b). 1. Relieve pressure, page 6. Disconnect power cord from outlet. 3. Install shroud (12) with screw (13). 2.
  • Page 51: Motor Brush Replacement

    Motor Brush Replacement Motor Brush Replacement See Wiring Diagram, page 27. 2. Push each cap (A) into place over brush. Orient each cap with the two projections on either side of Removal the brush lead. You will hear a snap when cap is securely in place.
  • Page 52: Control Board Replacement

    Control Board Replacement Control Board Replacement See Wiring Diagram, page 27. 7. Remove three screws (11) securing control board to housing (two are located on the front and one on the back next to the power cord). Removal 1. Relieve pressure, page 6. Disconnect power cord from outlet.
  • Page 53 Control Board Replacement Installation 3. Slide control board into place on side of motor front endbell. 1. Push grommet and power cord wires into strain relief in control board (18). Strain Relief Grommet ti6122a 2. Connect power cord connectors to terminals indi- ti9154a cated on control board (18).
  • Page 54: Fuse Replacement

    Fuse Replacement Fuse Replacement 3. Remove two screws (5) and toolbox (3) (190 Series A). 4. Remove two screws (11) and front cover (32). Remove screw (13) and shroud (12) (see illustra- If the fuse is blown, check for: tion, page15). •...
  • Page 55: Pressure Control Assembly Replacement

    Pressure Control Assembly Replacement Pressure Control Assembly Replacement See Wiring Diagram, page 27. 7. Pull wires through hole (K). 8. Turn pressure control knob (17) counter clockwise as far as you can to access flats on either side of pressure control. Removal 9.
  • Page 56 Pressure Control Assembly Replacement Installation 3. Apply loctite to pressure control knob (B) threads. 4. Screw pressure control threads (B) into manifold and torque to 150 in-lb (17.0 N.m). Caution Be careful when tightening pressure control knob that wires are not pinched between pressure control and fluid manifold.
  • Page 57: Drain Valve Replacement

    Drain Valve Replacement Drain Valve Replacement Installation 1. Install new seat gasket (44a) and valve seat (44b) on end of drain valve. 2. Screw drain valve (44) into filter manifold (43). Removal Torque to 120 to 130 in-lb. 1. Relieve pressure, page 6. Disconnect power cord 3.
  • Page 58: Drain Line Replacement

    Drain Line Replacement Drain Line Replacement Removal Installation 1. Cut drain line (49) from barbed fitting (51). 1. Screw barbed fitting (51) into filter manifold (43). 2. Unscrew barbed fitting from filter manifold (43). 2. Push drain line (49) onto barbed fitting. To make drain line more pliable and easier to install To reuse existing barbed fitting (51) and drain line over barbed fitting, heat end of drain line (49) with a...
  • Page 59: Power Cord Replacement

    Power Cord Replacement Power Cord Replacement See Wiring Diagram, page 27. Installation 1. Connect green ground wire (G) to frame with green ground screw (20). Be sure green ground wire ter- minal faces up or wires could get caught in shroud. Removal 2.
  • Page 60: Motor Replacement

    Motor Replacement Motor Replacement 7. Remove two screws (4) and filter manifold (43). 8. Remove green ground screw (20) and ground wire See Wiring Diagram, page 27. (G) from motor endbell. 9. Remove cover (14). Remove four screws (4) and motor (57) from frame (1).
  • Page 61: 120V Wiring Diagram

    120V Wiring Diagram 120V Wiring Diagram from Motor Red (+) 2 x Yellow Black (-) Replaceable Fuse Pressure Control Assembly ON/OFF Switch ti5643a Black Capacitor Power White Plug Green ti5643 311990H...
  • Page 62 Parts Parts ti9157a 311990H...
  • Page 63: Parts List

    Parts List Parts List Part Description Part Description 115099 WASHER, garden hose 288216 FRAME, cart, hi 15J744 HOSE, cpld 287489 HANDLE, cart 57❖ MOTOR, electric, 120V 117493 SCREW, mach, hex washer hd 255157 190 ES; includes 57a, 57b 109032 SCREW, mach, pnh 249040 210 ES;...
  • Page 64: Parts Drawing

    Parts Drawing Parts Drawing ti9159a Parts List Part Description Part Description 195811 LABEL, instruction 15K092 TUBE, drain 288503 TOOL BOX, assembly (190 244035 DEFLECTOR, barbed Series A) M70809 FITTING, barbed, hose 117493 SCREW, mach, hex washer hd 104361 O-RING 117501 SCREW, mach, slot hex wash hd 243080 FILTER, fluid 255169 CONTROL, pressure, 120V;...
  • Page 65 With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.
  • Page 66 For the latest information about Graco products, visit www.graco.com. TO PLACE AN ORDER, contact your Graco distributor or call 1-800-690-2894 to identify the nearest distributor. All written and visual data contained in this document reflects the latest product information available at the time of publication.

This manual is also suitable for:

190es 261825210es 261830