Error Messages
Angle
STN Setup has to be in F1/F2
You selected
Press any key to return to the previous screen. Then go to Station Setup and take
F1/F2 measurement to the BS.
Cogo
NO Result
The system was unable to calculate an area because points were not entered in the
correct order.
Press any key to return to the Cogo menu. Then enter the points in the correct order.
Same Coordinate
The point or coordinate that you entered is identical to the previous input point.
Press any key to return to the point input screen. Then use a different point.
XY-coordinate is required
The input point does not have XY (NE) coordinates.
Press any key to return to the point input screen. Then enter a point that has X and
Y coordinates.
Communications
If an error is detected during uploading of data, the Nivo instrument aborts the upload
process and displays one of the following messages.
Check Data
There are errors in the uploaded data. The uploaded data contains errors, such as an
alphabetic character in a coordinate field.
Press any key. Then check the specified line in the data.
DUPLICATE PT
The uploaded data contains a duplicate PT.
Press any key. Then check the specified point in the data.
B
Tip – If the existing point is a UP, CC, or MP record, and is not referred by ST or BS, then it will
be overwritten by the uploaded record. No error message appears.
PT MAX20 chars
The uploaded data contains a PT with a name or number that is longer than 20 digits.
Press any key. Then check the specified line in the data.