Disassembly Procedures
!
WARNING
Flame Sensor
1. Disconnect power supply to unit.
2. Remove service access panel, see "Service Access
Panel" procedure.
3. Close main gas shut-off valve.
4. Disconnect and label wire terminals from flame
sensor.
5. Remove screws securing flame sensor to burner
housing.
Ignitor
and
bracket
Air
shutter
6. Reverse procedure to reassemble.
Burner Housing and Heat Shroud
1. Disconnect power supply to unit.
2. Remove service access panel, see "Service Access
Panel" procedure.
3. Remove burner tube, ignitor, and bracket, see
"Burner Tube, Ignitor, and Bracket" procedure.
4. Remove screw securing burner housing to heat
shroud.
5. Remove screw securing front of burner housing to
dryer base.
6. Carefully remove burner housing out the front of unit.
7. Remove components attached to burner tube.
8. Remove screws securing heat shroud to heater box
and remove.
9. Reverse procedure to reassemble.

Limit Thermostat (Gas Models)

1. Disconnect power supply to unit.
2. Remove service access panel, see "Service Access
Panel" procedure.
3. Disconnect and label wire terminals from limit
thermostat.
4. Remove screws securing limit thermostat to burner
housing.
28
White
ceramic
portion
Burner
tube
16023020
To avoid risk of electrical shock, personal injury, or
death, disconnect power and shut-off gas supply valve
to unit before servicing.
Air shutter
adjustment
screw
1/8" Pipe plug
(For checking manifold pressure)
5. Reverse procedure to reassemble.

Heating Element (Electric Models)

1. Disconnect power supply to unit.
2. Remove service access panel, see "Service Access
Panel" procedure.
3. Remove screws securing heating element to heater
box.
4. Pull downward on heating element to remove from
heater box.
5. Disconnect and label wire terminals to element and
components.
6. Remove screws securing components to heating
element, and transfer components to new heating
element.
Limit
thermostat
Thermal
fuse
7. Reverse procedure to reassemble.
NOTE: Verify wire terminals are tightly connected to
heating element and components.
Limit
thermostat
Air shutter
Heater
assembly
©2004 Maytag Services