Graco 234124 Instructions-Parts List Manual page 8

Aluminum and stainless steel air-operated diaphragm pumps
Table of Contents

Advertisement

KEY FOR FIG. 4
A
Air supply line
B
Bleed-type master air valve
(required for pump)
C
Air regulator
D
Air line quick disconnect
E
Master air valve (for accessories)
F
Air line filter
G Fluid suction line
J
Fluid drain valve (required)
K
Fluid shutoff valve
L
Fluid line
M Wall mounting bracket
Y
Ground wire (required; see page 4
for installation instructions)
Fig. 4
Changing the Orientation of the Fluid Inlet
and Outlet Ports
On aluminum pumps, the fluid inlet and outlet man-
ifolds have threaded ports on both ends. The pump is
shipped with a plug installed in one end of each man-
ifold, and the opposite end open. See Fig. 5. To
change the orientation of the inlet and/or outlet port,
remove the plug from one end of a manifold and install
it in the opposite end.
On stainless steel pumps, the fluid inlet and outlet
manifolds have threaded ports on one end only. The
pump is shipped with the ports facing the same direc-
tion. To reverse the orientation of the ports:
1. Remove the screws and nuts holding the inlet
and/or outlet manifold to the covers.
2. Reverse the manifold and reattach. Install the
screws and torque to 120–150 in-lb (14–17 N.m).
8
308479
Installation
E
F
C
D
G
KEY
N
1/2 npt(f) air inlet port
P
Muffler. Air exhaust port is 3/4 npt(f)
R
1 npt(f) fluid inlet port
S
1 npt(f) fluid outlet port
106 Manifold and cover screws
3
Air valve screws
2
3
N
P
Fig. 5
TYPICAL WALL-MOUNT INSTALLATION
B
A
K
L
J
Y
M
02649B
Apply medium-strength
1
(blue) LoctiteR or equiv-
alent to the threads, and
torque to 120–150 in-lb
(14–17 N.m).
Torque to 50–60 in-lb
2
(5.6–6.8 NSm).
1
106
S
1
106
R
02632C

Advertisement

Table of Contents
loading