27, 36, 45, 54, 63, 72
28, 37, 46, 55, 64, 73
29, 38, 47, 56, 65, 74
30, 39, 48, 57, 66, 75
31, 40, 49, 58, 67, 76
32, 41, 50, 59, 68, 77
33, 42, 51, 60, 69, 78
34, 43, 52, 61, 70, 79
81, 97
82, 98
83, 99
84, 100
85, 101
86, 102
87, 103
88, 104
90, 106
91, 107
92, 108
93, 109
https://www.zennio.com
1 Bit
I
C - W - -
DPT_Start
1 Bit
O
C R - T -
DPT_Switch
1 Byte
O
C R - T -
DPT_Scaling
1 Byte
O
C R - T -
DPT_HVACMode
1 Bit
I
C - W - -
DPT_Enable
1 Bit
I
C - W - -
DPT_Enable
1 Bit
I
C - W - -
DPT_Start
1 Bit
I
C - W - -
DPT_Start
2 Bytes I/O
C R W - -
DPT_TimePeriodSec
1 Bit
I
C - W - -
DPT_Start
1 Bit
I
C - W - -
DPT_Enable
1 Bit
I
C - W - -
DPT_Enable
1 Bit
I
C - W - -
DPT_Start
1 Bit
I
C - W - -
DPT_Start
2 Bytes
I
C - W - -
DPT_Value_Lux
2 Bytes
I
C - W - -
DPT_Value_Lux
1 Byte
I
C - W - -
DPT_Scaling
1 Byte
I
C - W - -
DPT_Scaling
2 Bytes
I
C - W - -
DPT_Value_Lux
1 Byte
I
C - W - -
DPT_Scaling
1 Byte
O
C R - T -
DPT_Scaling
2 Bytes I/O
C R W - -
DPT_TimePeriodSec
1 Bit
I
C - W - -
DPT_Switch
4 Bit
I
C - W - -
DPT_Control_Dimming
1 Byte
I
C - W - -
DPT_Scaling
1 Bit
O
C R - T -
DPT_Switch
0/1
[Cx] External Motion Detection
0/1
[Cx] Output (Binary)
0% - 100%
[Cx] Output (Scaling)
1=Comfort
2=Standby
3=Economy
[Cx] Output (HVAC)
4=Building
Protection
0/1
[Cx] Lock Status
0/1
[Cx] Lock Status
0/1
[Cx] Force State
0/1
[Cx] External Switch
0 - 65535
[Cx] Length of Detection
0/1
[CLCx] External Motion Detection
0/1
[CLCx] Lock Status
0/1
[CLCx] Lock Status
0/1
[CLCx] Force State
0/1
[CLCx] External Switch
[CLCx] Setpoint
[CLCx] Setpoint During Day
0% - 100%
[CLCx] Setpoint
0% - 100%
[CLCx] Setpoint During Day
[CLCx] Setpoint During Night
0% - 100%
[CLCx] Setpoint During Night
0% - 100%
[CLCx] Dimming Value
0 - 65535
[CLCx] Length of Detection
[CLCx] Manual Control: On/Off
0/1
(Input)
0x0 (Stop)
0x1 (Dec. by 100%)
...
0x7 (Dec. by 1%)
[CLCx] Manual Control: Relative
0x8 (Stop)
Dimming (Input)
0xD (Inc. by 100%)
...
0xF (Inc. by 1%)
[CLCx] Manual Control: Absolute
0% - 100%
Dimming (Input)
[CLCx] Manual Control: On/Off
0/1
(Output)
1 = Motion detected by an
external sensor
Binary Value
0-100%
Auto, Comfort, Standby, Economy,
Building Protection
0 = Unlock; 1 = Lock
0 = Lock; 1 = Unlock
0 = No Detection; 1 = Detection
0 = No Detection; 1 = Detection
1-65535 s.
1 = Motion detected by an
external sensor
0 = Unlock; 1 = Lock
0 = Lock; 1 = Unlock
0 = No Detection; 1 = Detection
0 = No Detection; 1 = Detection
Setpoint Value (1-2000)
Setpoint Value (1-2000)
Setpoint Value (1-100)%
Setpoint Value (1-100)%
Setpoint Value (1-2000)
Setpoint Value (1-100)%
Dimming Value (%)
1-65535 s.
1-Bit Control
4-Bit Control
1-Byte Control
1-Bit Control
Technical Support:
https://support.zennio.com
EyeZen TP v2
11