4
Technical description of the burner
4.1
Burner designation
Range :
R
Fuel :
R
S
160
BASIC DESIGNATION
4.2
Burner categories
Country of destination
AT, CH, CZ, DK, EE, FI, GR, HU, IS, IT, LT, NO, SE, SI, SK
ES, GB, IE, PT
Technical description of the burner
S
Natural gas
L
Light oil
LS
Light oil / Natural gas
N
Heavy oil
Size
Adjustment :
E
EV
M
P
Emission :
Head :
E
BLU
TL
EXTENDED DESIGNATION
BE
LV
CY, MT
BE
LU, PL
DE
FR
NL
Electronic cam
Electronic cam and variable speed (with Inverter)
Mechanical cam
Proportional air/gas valve
C01 or ...
Class 1 EN676
MZ
Class 2 EN676
BLU
Class 3 EN676
MX
Class 3 EN676
TC
Standard head
TL
Long head
Flame control system :
FS1
Standard (1 stop every 24h)
FS2
Continuous operation (1 stop every 72h)
Electrical supply of the system :
3/400/50
3/230/50
3/400-230/50
FS2
3/400/50
230/50/60
7
GB
3N / 400V / 50Hz
3 / 230V / 50Hz
3N / 400V-230V / 50Hz
Voltage of auxiliaries :
230/50/60
230V / 50-60Hz
110/50/60
110V / 50-60Hz
Gas category
I2E(R)
I2H
I3B/P
I3P
II2E3B/P
II2ELL3B/P
II2Er3P
II2H3B/P
II2H3P
I2E - I2 (43,46 ÷ 45,3 MJ/m3 (0°C))
Tab. A
20067467