Type Tests And Environmental Conditions - Advantech ICR-2431 User Manual

Lte industrial router
Hide thumbs Also See for ICR-2431:
Table of Contents

Advertisement

4.3 Type Tests and Environmental Conditions

Phenomena
Test
ESD
EN 61000-4-2
RF field AM
EN 61000-4-3
modulated
Fast transient
EN 61000-4-4
Surge
EN 61000-4-5
RF conducted
EN 61000-4-6
Radiated emission
EN 55032
Conducted
EN 55032
emission
Dry heat
EN 60068-2-2
Cold
EN 60068-2-1
Variation of
EN 60068-2-14
temperature
Dry heat, cyclic
EN 60068-2-30
Table 13: Type Tests and Environmental Conditions
Description
Test levels
Enclosure
CD
Enclosure
20 V/m, 80 MHz-1 GHz, LX
10 V/m, 1 GHz-6 GHz, L3
DC port
1 kV, 5/50 Tr/Th ns, 100 kHz, L2
ETH - FTP
1 kV, 5/50 Tr/Th ns, 100 kHz, L3
Binary input
1 kV, 5/50 Tr/Th ns, 100 kHz, L3
Binary output
1 kV, 5/50 Tr/Th ns, 100 kHz, L3
RS232
1 kV, 5/50 Tr/Th ns, 100 kHz, L3
RS485
1 kV, 5/50 Tr/Th ns, 100 kHz, L3
ETH
1 kV, 1.2/50(8/20) Tr/Th us, L2
RS485
1 kV, 1.2/50(8/20) Tr/Th us, L2
DC port
10 V, 0.15-80 MHz, 80%AM(1kHz), L3
ETH
10 V, 0.15-80 MHz, 80%AM(1kHz), L3
I/O ports
10 V, 0.15-80 MHz, 80%AM(1kHz), L3
RS232
10 V, 0.15-80 MHz, 80%AM(1kHz), L3
RS485
10 V, 0.15-80 MHz, 80%AM(1kHz), L3
Enclosure
Class B, 30 MHz-1 GHz, 1 GHz-6 GHz
DC power port
Class B, 150 kHz-30 MHz
Ethernet ports
Class B, 150 kHz-30 MHz
Serial ports
Class B, 150 kHz-30 MHz
RS232
Class B, 150 kHz-30 MHz
RS485
Class B, 150 kHz-30 MHz
Operating
Test Bb, storage +75 C
Storage
Test Bd, operation +85 C
Operating
Test Ab, storage -40 C
Storage
Test Ad, operation -40 C
Test Nb, -40 C / +75 C, 3h/3h, 2 cycles, 3 K/min
+55 C / +25 C, rel. humidity 95 %, 6 h-6 h
26
ICR-2431
6 kV, L3

Advertisement

Table of Contents
loading

Table of Contents