TROUBLESHOOTING (cont.)
PROBLEM
Dispense station
concentrate only
Dispense station
water only
PROBABLE CAUSE
Water solenoid
Concentrate out
Product pump not pumping
Pump not turning
24
REMEDY
Replace solenoid (24vdc) or check
wire connection between water
valve and main control board.
Replace refill concentrate container
or BIB
Check for proper counterclockwise
rotation of pump rollers. If coun-
terclockwise, replace pump tubing.
If clockwise, wire connection to
pump is reversed. Switch wires on
terminals.
A) Check speed setting on circuit
board and increase speed (turn
clockwise)
B) Check for d.c. power to pump mo-
tor. If yes, replace motor assy. If no,
check harness for proper continuity.
Then replace circuit board if needed.
44744.2 062912