Metal Parts

 In the ultrasonic bath, preheat 1 part OmegaSupreme with 10 parts clean water to a
temperature of 150˚F.
 Place the metal parts into the basket with the cavity containing heaviest residue
facing the bottom of the basket.
 Submerge the basket into the bath and rotate the housings (if applicable) keeping
them underneath the surface to allow air bubbles to be removed from the part.
 Clean the part for 5 minutes.
 Once completed, rotate the part 180˚ if the part facing opposite the ultrasonic
transducers is heavily soiled.
 If necessary, clean the part for an additional 5 minutes.
 Once the part is cleaned, remove from the bath and rinse using water that is 150˚F.
 Blow off the excess water using compressed air.
 Due to the heat of the metal, after being removed from the bath, it will dry quickly, on
its own ("flash dry").