3.2 Communication

The Redx inverter has an external data collector, users can choose either WIFI or 4G dataloggers
according to their requirements, and use their computer or mobile phone APP (Redx Power) to
monitor the inverter and battery status. The default datalogger in the device uses Wi-Fi
to connect to the customer's Wi-Fi router to establish an Internet connection. The installer will use
Bluetooth to connect to the datalogger and configure the device to connect the datalogger to the
local Wi-Fi router during the installation process. The inverter communicates with the battery
BMS using RS485.
RX-7000HY/5000HY Battery / Communication connector
Note: The communications connector will be pre-assembled to connect the inverter to
smartmeters and inverter to com1 port of bat1.

3.3 Installation

Step 1 Use a Hole Template to determine the installation position
Step 2 Installation of Expansion bolts
Step 3 Secure the wall hanging section
Step 4 Install the battery system on the wall mount
Step 5 Secure the connection between the battery systems
Step 6 Install the grounding section on the back of the battery system
Step 7 Install an External battery isolator between the Batteries and inverter
Step 8 Connect battery power cables
Step 9 Connect battery communication cables
Step 10 Install the battery system cover
Step 11 Complete the installation.