1.3 Electrical Safety

Grounding
For the equipment that needs to be grounded, install the ground cable first when installing the
equipment and remove the ground cable last when removing the equipment.
Do not damage the ground conductor.
Do not operate the equipment in the absence of a properly installed ground conductor.
Ensure that the equipment is connected permanently to the protective ground. Before operating the
equipment, check its electrical connection to ensure that it is securely grounded.
AC and DC Power
Do not connect or disconnect power cables with the power on. Transient contact between the
core of the power cable and the conductor will generate electric arcs or sparks, which may
cause fire or personal injury.
Before installing or removing a power cable, turn off the power switch.
Before connecting a power cable, check that the label on the power cable is correct.
If the equipment has multiple inputs, disconnect all the inputs before working with the
equipment.
A damaged power cable must be replaced by the manufacturer, service agent, or professionals
to avoid risks.
High voltage operations and installation of AC-powered facilities must be performed by qualified
personnel.
ESD
The static electricity generated by human bodies may damage the electrostatic-sensitive
components on boards, for example, the large-scale integrated (LSI) circuits.
Wear ESD gloves or a well-grounded ESD wrist strap when touching the device or handling boards
or application-specific integrated circuits (ASICs).
When holding a board, hold its edge without touching any components. Do not touch the components
with your bare hands.
Package boards with ESD packaging materials before storing or transporting them.