Creating Reports - R&S EMC32 Application Note

Emi automotive band evaluation
Table of Contents

Advertisement

Figure 41: After end of test all data are collected in result tables including tables
with the outcome of data reduction per Band
Table 4-2: Description of the naming convention for tables
Table name
<Sub-range name>_Auto
<Sub-range name>_DR_D1
<Sub-range name>_DR_D2
Result Table
Table 4-3: Naming convention for graphics
Graphics name
<Sub-range name>
<Test template name>
5

Creating Reports

We start with an empty Report setup in the report generator.
01.00
Description
This table contains the measurement values
This table contains the result of the Data Reduction
acc. to limit line 1 and detector 1 (if data reduction is
enabled)
This table contains the result of the Data Reduction
acc. to limit line 2 and detector 2 (if data reduction is
enabled)
Active table for the next measurement. After test stop
this table is empty.
Description
For each sub-range one graphics is generated
This graphics is ready to take over the trace of the
next measurement. It is only visible in measurement
mode, in analysis mode it can be floating.
Rohde & Schwarz EMI Automotive Band Evaluation with R&S©EMC32-K51 – 1SP07- 35
Creating Reports