R&S EMC32 Application Note page 33

Emi automotive band evaluation
Table of Contents

Advertisement

Delete Measurement
Copy Current
Trace
01.00
the calculation or limit and margin.
The method is defined as followed
A specific column, which shall be compared, can be selected from
Resultant table. This shall be done in Evaluation column dialog
Select the pre-defined limit lines table either from limit lines table used
in the current test or from the Global limit lines. This shall be done in
the Limit Lines dialog.
Column (from the resultant table) will be compared and added to the
pre-defined limits column in the limit line table.
The margin to the limit line will be calculated and a new table will be
created with margin result.
The destination file (Output File) can be used again as an input file
(select 'From this test' as the result type) if limit and margin values
need be calculated for more than one detector trace.
If the measurement run is stopped the current measurement result can be
deleted by clicking this button. All graphics and tables (active tables) are
cleared.
The measurement results trace(s) from a current sweep or scan
test will be overwritten when repeating the same measurement.
To save certain results you can use the function 'copy current
trace' on the toolbar. This way the current result file will
automatically be renamed to "Result Table (<time>)" or any
name can be selected and will be added to the diagram.
Rohde & Schwarz EMI Automotive Band Evaluation with R&S©EMC32-K51 – 1SP07- 33
Running an EMI Band Evaluation Test

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emc32-k51

Table of Contents