Your gas barbecue should be serviced annually by a competent registered person.

TROUBLE SHOOTING

PROBLEM
Burners will not light
using the ignition
system
Burner will not light
with a match
Low flame or
flashback (fire in
burner tube-a hissing
or roaring noise may
be heard)

Specifications

UK
Gas (LPG)
Pressure and type of gas
Power
Consumption
Regulator
Gas hose
Ignition
Grill size
Dimensions
POSSIBLE CAUSE
1. LP gas cylinder is empty
2. Faulty regulator
3. Obstructions in burner
4. Obstructions in gas jets or gas hose
5. Electrode wire loose or disconnected
on electrode or ignition unit
6. Electrode or wire is damaged faulty
pushbutton igniter
1. LG gas cylinder is empty
2. Faulty regulator
3. Obstructions in burner
4. Obstructions in gas jets or gas hose
1. LP gas cylinder too small
2. Obstructions in burner
3. Obstructions in gas jets or gas hose
4. Windy conditions
I3+(28-30/37)
G30 Butane at 28-30 mbar G31 Propane at 37 mbar
Butan 28-30 mbar / Propan 37 mbar
3 x 3 kW + 2,5 kW = 11,5 kW
Butan: 836 (g/h) a Propan: 820 (g/h)
The regulator that is used must be CE approved
The gas hose that is used must be CE approved (max length 1.5 m)
Central piezo
60 x 42 cm
122 x 57 x 112 cm
SOLUTION
1. Replace with full cylinder
2. Have regulator checked or replace
3. Clean burner
4. Clean jets and gas hose
5. Reconnect wire
6. Change electrode and wire Change
igniter
1. Replace with full cylinder
2. Have regulator checked or replace
3. Clean burner
4. Clean jets and gas hose
1. Use larger cylinder
2. Clean burner
3. Clean jets and gas hose
4. Use BBQ in a more sheltered position