  • Page 1: Table Of Contents

    Tranquility ® (TZ) Series Table of Contents Model Nomenclature General Information Unit Physical Data Horizontal Installation TZ – Horizontal Dimensional Data Horizontal Installation Field Conversion of Air Discharge Horizontal Installation Vertical Installation Piping Installation vFlow Heat Pump Applications Overview ® Water-Loop Heat Pump Applications Ground-Loop Heat Pump Applications Ground-Loop and Ground Water Heat...
  • Page 2 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 This Page Intentionally Left Blank C l i m a t e M a s t e r Wa t e r - S o u r c e H e a t P u m p s...
  • Page 3: Model Nomenclature

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 4: General Information

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 General Information ⚠...
  • Page 5 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 6: Unit Physical Data

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Unit Physical Data Tranquility 22 Two-Stage (TZ) Series (60Hz Only)
  • Page 7: Horizontal Installation

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 8: Tz - Horizontal Dimensional Data

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 TZ –...
  • Page 9: Horizontal Installation

    UV based anti-bacterial systems may damage (e.g. louvered door). Therefore, filter rails are the industry coated air coils. standard and are included on ClimateMaster commercial heat pumps for the purposes of holding the filter only. For ducted return applications, the filter rail must be removed and replaced with a duct flange or filter frame.
  • Page 10: Field Conversion Of Air Discharge

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Field Conversion of Air Discharge Overview - Horizontal units can be field converted Figure 4: Left Return Side to Back...
  • Page 11: Horizontal Installation

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 12: Vertical Installation

    (e.g. louvered door). Therefore, filter rails are the industry standard and are included on ClimateMaster commercial heat pumps for the purposes of holding the filter only. For ducted return applications, the filter rail must be removed and replaced with a duct flange or filter frame.
  • Page 13 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 14: Piping Installation

    Optional pressure-rated hose assemblies designed transmitted through the hoses to the structure, causing (0.6m Length Standard) specifically for use with ClimateMaster units are available. unnecessary noise complaints. Similar hoses can be obtained from alternate suppliers. Figure 11: Supply/Return Hose Kit Supply and return hoses are fitted with swivel-joint fittings at one end to prevent kinking during installation.
  • Page 15: Vflow ® Heat Pump Applications Overview

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 16 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 vFlow Heat Pump Applications Overview, Cont’d.
  • Page 17 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 18: Water-Loop Heat Pump Applications

    [2.9 and 4.5 l/m per kW] of cooling capacity. mechanical room plumbing. Consideration should be given ClimateMaster recommends 3 gpm per ton [3.9 l/m per to insulating the piping surfaces to avoid condensation. kW] for most applications of water loop heat pumps. To...
  • Page 19: Ground-Loop Heat Pump Applications

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 20: Ground-Loop And Ground Water Heat Pump Applications

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Ground-Loop and Ground-Water Heat Pump Applications Ground-Loop Heat Pump Applications Typical Closed Loop with Central Pumping (unit with...
  • Page 21: Ground-Water Heat Pump Applications

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 22 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Ground-Water Heat Pump Applications, Cont’d.
  • Page 23: Water Quality Standards

    All closed water loop systems should undergo water quality testing and be maintained to the water quality standards listed in this table. CLIMATEMASTER WATER QUALITY STANDARDS For Closed-Loop and Open-Loop Systems...
  • Page 24 R e v . : O c t o b e r 5 , 2 0 2 1 Water Quality Standards, Cont'd. 1. The ClimateMaster Water Quality Table provides Hydrogen Sulfide has an odor of rotten eggs. If one α...
  • Page 25 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 26 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Water Quality Standards, Cont'd.
  • Page 27: Electrical - Line Voltage

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 28 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Electrical –...
  • Page 29: Electrical Data

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 30: Electrical - Power & Low Voltage Wiring

    DXM2 control allows the field selection of low water (or temperature when using an antifreeze solution. All water-antifreeze solution) temperature limit by clipping ClimateMaster units operating with entering water jumper JW3, which changes the sensing temperature temperatures below 60°F [15.6°C] must include the associated with thermistor LT1.
  • Page 31: Electrical - Low Voltage Wiring

    Comp illustrate typical slow closing water control valve wiring for Relay 3/8” standoff Taco 500 series (ClimateMaster P/N AVM) and Taco SBV Acc2 Relay series valves. Slow closing valves take approximately 60 seconds to open (very little water will flow before 45 seconds).
  • Page 32: Electrical - Low Voltage Wiring For Non-Vflow ® Units

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Electrical –...
  • Page 33: Electrical - Thermostat Wiring

    Practically any heat pump thermostat will work Sensor (Optional) the wall so that it appears level and so the thermostat with ClimateMaster units, provided it has the correct Remote Indoor wires protrude through the middle of the back plate. Mark number of heating and cooling stages.
  • Page 34: Blower Performance Data

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Blower Performance Data TZ Standard Unit - No Reheat Cooling Mode...
  • Page 35: Ecm Blower Control

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 36: Tz Series Wiring Diagram Matrix

    Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 TZ Series Wiring Diagram Matrix All current diagrams can be located online at climatemaster.com/commercial/literature/wiring-diagrams. 208v/1 - 265v/1 208v/3 460v/3 Unit Controller...
  • Page 37 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 38 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 DXM2 Controls, Cont’d.
  • Page 39 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 40: Dxm2 Layout And Connections

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 DXM2 Layout and Connections Communicating Service tool...
  • Page 41: Dxm2 Controls

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 42 Resistance Temp (ºC) Temp (ºF) Temp (ºC) Temp (ºF) (kOhm) (kOhm) cool thermostats can be used with the DXM2, as well as -17.8 85.34 131.0 2.99 ClimateMaster communicating thermostats (ATC32). -17.5 84.00 132.8 2.88 -16.9 81.38 134.6 2.77 10.4 61.70 136.4...
  • Page 43: Unit Starting And Operating Conditions

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 44: Piping System Cleaning And Flushing

    ClimaDry II to operate properly. Sizes 024-036 Sizes 048-060 4. Verify that all strainers are in place (ClimateMaster Closed Closed recommends a strainer with a #20 stainless steel wire mesh).
  • Page 45: Unit And System Checkout

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 46: Unit Start-Up Procedure

    5. Two factors determine the operating limits of c. Check for warm air delivery within a few minutes ClimateMaster heat pumps, (a) return air temperature, after the unit has begun to operate. and (b) water temperature. When any one of these factors is at a minimum or maximum level, the other d.
  • Page 47: Unit Operating Conditions

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 48 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Unit Operating Conditions Table 11: TZ Series Typical Unit Operating Pressures and Temperatures (60Hz –...
  • Page 49 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 50: Preventive Maintenance

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Preventive Maintenance Water Coil Maintenance - (Direct ground water these filters (in the opposite direction of the normal air...
  • Page 51: Troubleshooting

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 52 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Troubleshooting, Cont’d.
  • Page 53: Dxm2 Process Flow Chart

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 54: Functional Troubleshooting

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Functional Troubleshooting Fault Clg Possible Cause...
  • Page 55 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 56: Performance Troubleshooting

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Performance Troubleshooting Symptom Htg Clg Possible Cause...
  • Page 57 Restricted metering device Check superheat and subcooling per chart - replace Check pump operation or water valve operation/setting Reduced water flow Plugged strainer or filter - clean or replace T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y in heating Check water flow adjust to proper flow rate Water temperature out of range...
  • Page 58: Start-Up Log Sheet

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Start-Up Log Sheet Installer: Complete unit and system checkout and follow unit start-up procedures in the IOM.
  • Page 59: Functional Troubleshooting

    Model Number: ________________________ Serial Number: ________________________ T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Date: ________________________ Packaged Unit Refrigeration Schematic 22 ( TZ ) Series...
  • Page 60: Warranty (U.s. & Canada)

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Warranty (U.S.
  • Page 61: Warranty (International)

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 62 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S 22 ( TZ ) Series Tranquility ® R e v . : O c t o b e r 5 , 2 0 2 1 Notes: C l i m a t e M a s t e r Wa t e r - S o u r c e H e a t P u m p s...
  • Page 63 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y 22 ( TZ ) Series Tranquility ®...
  • Page 64: Revision History

    ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications.