Pulsar PSBS 5024C Manual

Buffer, switched mode power supply unit
Hide thumbs Also See for PSBS 5024C:

Advertisement

Quick Links

PSBS 5024C
v.1.0
PSBS 27,6V/5A/2x17Ah
Buffer, switched mode power supply unit.
EN
Edition: 2 from 18.09.2012
Supersedes edition: 1 from 02.03.2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSBS 5024C and is the answer not in the manual?

Questions and answers

Summary of Contents for Pulsar PSBS 5024C

  • Page 1 PSBS 5024C v.1.0 PSBS 27,6V/5A/2x17Ah Buffer, switched mode power supply unit. Edition: 2 from 18.09.2012 Supersedes edition: 1 from 02.03.2012...
  • Page 2: Table Of Contents

    OPTIONAL CONFIGURATIONS OF THE PSU: www.pulsar.pl (visualisation available on: 1. Buffer power supply unit PSBS 27,6V/8x0,5A/2x17Ah - PSBS 5024C + LB8 8x0,5A (AWZ578, AWZ580) + 2x17Ah 2. Buffer power supply unit PSBS 27,6V/4x1A/2x17Ah - PSBS 5024C + LB4 4x1A (AWZ575 or AWZ576) + 2x17Ah...
  • Page 3: Block Diagram

    - PSBS 5024C + 2xRN25024(27,6V/24V) + 2x17Ah 4. Buffer power supply unit PSBS 27,6V/2x24V/8x0,5A/2x17Ah - PSBS 5024C + 2xRN25024(27,6V/24V) + 2xLB4 8x0,5A (AWZ574 or AWZ576) + 2x17Ah 5. Buffer power supply unit PSBS 27,6V/2x5V÷18V/2x2A÷1,3A/2x17Ah - PSBS 5024C + 2xDCDC20 (2x5V÷18V/2x2A÷1,3A) + 2x17Ah 6.
  • Page 4 PSBS5024C +BAT - DC supply battery output [11] (+BAT= red, -BAT = black) FAC - AC absence technical output –OC type (open collector) [12] hi-Z level = status: AC power failure L level = status: AC supply FPS - technical output of the PSU operation status – OC type (open collector)
  • Page 5: Specifications

    PSBS5024C Fig.3. The view of the PSU. 1.4. Specifications: - electrical specifications (tab.3) - mechanical specifications (tab.4) - operation safety (tab.5) - operating specifications (tab.6) Electrical specifications (tab. 3). Mains supply 230V AC (-15%/+10%) Current consumption 1,1A Power frequency...
  • Page 6 PSBS5024C 200% ÷ 250% of the PSU power, hiccup mode– 13A/200ms and/or Short-circuit protection SCP fuse damage in the battery circuit (fuse-element replacement required) 110% ÷ 150% of the PSU power – electronic. Overload protection OLP Disconnection of the PSU outputs – automatic return after...
  • Page 7: Installation

    PSBS5024C 2. Installation. 2.1 Requirements The buffer PSU is to be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V/AC interference and low-voltage installations. The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal relative humidity (RH=90% maximum, without condensation) and temperature from -10°...
  • Page 8: Operating Status Indication

    PSBS5024C 3. Operating status indication. 3.1 LED indication. The PSU is equipped with two diodes on the front panel: RED LED: • on – the PSU is supplied with 230V AC • off – no 230V AC supply GREEN LED: •...
  • Page 9: Battery-Assisted Operation

    GENERAL WARRANTY CONDITIONS 1. Pulsar K. Bogusz Sp.j. (the manufacturer) grants a two-year warranty for the equipment, starting from the initial product date of purchase placed on the receipt. 2. If a purchase proof is missing, a three-year warranty period is counted from the device’s production date.
  • Page 10 PSBS5024C Pulsar K.Bogusz Sp.j. Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 e-mail: biuro@pulsar.pl, sales@pulsar.pl http:// www.pulsar.pl, www.zasilacze.pl...

Table of Contents