Tiziano TZ 420 oven technical data ..............8 Tiziano TZ 425 oven technical data ..............17 Before the installation, read the content of this manual Tiziano TZ 230 oven technical data ..............26 carefully: it contains important information regarding product Tiziano TZ 430 oven technical data ..............35...
• check that the cooking chamber capacity is adequate to the owner's needs. The “Technical data” section from page contains the weights and dimensions of the ovens and cooking chambers. °C 400 °C 400 °C 400 °C 400 Fig.1 Ed. 0423 - 70702500 REV03 TIZIANO - Pre-installation...
Page 4
Checks before purchasing • it is possible to maintain a minimum distance between the oven Inform the owner about the necessary electrical ar- Survey the installation room to make sure it is adequate. walls, other appliances, objects combustible rangements (activities to be carried out by a qualified and the electrician) materials...
Page 5
50 mm 50 mm be necessary to move the oven from [ 1,97 in.] [ 1,97 in.] its housing with suitable systems. Fig.4 Ed. 0423 - 70702500 REV03 TIZIANO - Pre-installation...
OVEN TECHNICAL DATA Electrical data | STANDARD OVENS Power Average Customer Power Average Customer Power Absorption Cable type Power Absorption Cable type Oven model supply consumption panel prot. Oven model supply consumption panel prot. (kW) (Nxmm (kW) (Nxmm (kWh) (NxA) (kWh) (NxA) TZ420/1M-C5-CP...
The original language used to prepare this manual is English: ed in this manual can cause damages, injuries or the Manufacturer is not responsible for any translation/ fatal accidents and null and void the warranty. interpretation or print errors. Ed. 0423 - 70702500 REV03 TIZIANO - Pre-installation...
Installation Transport Fig.5 Fitted with personal protection equipment, transport the appli- ance to the installation location. Use a suitable vehicle capable of withstanding the weight of the same. Model single double Model single double TZ420 51kg / 112.4lb 90kg / 198.4lb TZ430 85kg / 187.3lb 148kg / 326.2lb TZ425...
Page 56
Installation Year of production Model MADE IN ITALY 2020 Mod. TZ435/2M−C5−CP Absorption 10,4 VOLT VOLT 3 400−50Hz °C 400 S/N TZ4352MC5CP 20041451 °C 400 Voltage Serial number Fig.10 extraction system extraction system damper draught switch Fig.11...
• must be connected to a compliance with the regulations in force (0.03A A type); • must be connected to an omnipolar circuit breaker allow- earth ing complete disconnection in overvoltage III category con- ditions. Ed. 0423 - 70702500 REV03 TIZIANO - Pre-installation...
Page 58
Installation The Manufacturer accepts no liability for failure to comply with the above. If required, the cable must be replaced by the Dealer or its technical service or by a person with °C 400 similar qualifications to prevent any risk. 20 0 30 0 10 0...
Page 59
FU1,2,3,4 Fuses SX.y Button lights Transformer 50VA, 230/12V AC This wiring diagram is associated with ovens produced after 02/03/2022 for all serial numbers starting from 22031742 and later HL1,2 Cooking chamber lights Ed. 0423 - 70702500 REV03 TIZIANO - Pre-installation...
Page 60
Installation AC 3 230 °C °C °C Abbreviation Description RA1,2 Top heating elements RB1,2 Bottom heating elements Terminal board ST1,2 Safety thermostat SA1,2 General ignition KM / KMS 1-2 Main contactor TAA1,2 Top heating element regulator TAB1,2 Bottom heating element regulator SAL1,2 Chamber light switching on HLA1,2...
Page 61
FU1,2,3,4 Fuses SX.Y Button lights Transformer 50VA, 230/12V AC This wiring diagram is associated with ovens produced after 02/03/2022 for all serial numbers starting from 22031742 and later HL1,2 Cooking chamber lights Ed. 0423 - 70702500 REV03 TIZIANO - Pre-installation...
Page 62
Installation AC 208 AC 240 °C °C °C FU3 T2.5A 250V FU4 T2.5A 250V Abbreviation Description FU1 1A 240V FU2 1A 240V Top heating elements Bottom heating elements Rotary switch Main contactor Chamber safety thermostat General ignition Chamber light switching on Chamber contactor Top heating element regulator Bottom heating element regulator...
Page 63
Chamber light switching on Chamber contactor Top heating element regulator Bottom heating element regulator Top heating element heating light Bottom heating element heating light Fuses Transformer 20VA, 230/12V AC Cooking chamber lights Ed. 0423 - 70702500 REV03 TIZIANO - Pre-installation...
Installation Pre-testing and final inspection √ Positioning checks The oven is checked and tested in the Manufacturer’s plant be- Is the installation room adequate and compliant with regulations? (correct ventilation, maximum/minimum temperature, fore being delivered to the customer. etc.) The “production process check sheet” enclosed with it guaran- Is the appliance perfectly level? tees that each...
Manufacturer. 20 0 30 0 10 0 °C 40 If manual cleaning is not enough, use the PYROLYSIS function, 50 0 60 0 °C 400 see page °C °C 400 Fig.15 Fig.16 Ed. 0423 - 70702500 REV03 TIZIANO - Pre-installation...
Page 66
Maintenance and cleaning | replacing components CLEANING THE CHAMBER WITH THE PYROLYSIS FUNCTION Pyrolysis is a thermochemical crystallization process of food residues that have deposited in the cooking chamber, which takes place by bringing the oven up to 400 °C/752 °F. Before starting the pyrolysis, remove the coarser food residues with a natural fibre brush.
Never press the bulb glass with your bare hands; always wear gloves. °C 400 Never switch the oven on without having refitted the bulb pro- tective glass; replace it straight away if it breaks. °C 400 Fig.21 Ed. 0423 - 70702500 REV03 TIZIANO - Pre-installation...
Page 68
Maintenance and cleaning | replacing components REPLACING THE REFRACTORY BRICKS Fig.22 REPLACING THE DOOR HANDLE Fig.23 °C 400 °C 400 20 0 30 0 10 0 °C 40 50 0 60 0 20 0 30 0 10 0 °C 40 50 0 60 0 20 0...
Page 70
CUPPONE since 1963 CUPPONE S.R.L. Via Sile, 36 31057 Silea (TV) - ITALY T +39 0422 361143 F +39 0422 360993 info@cuppone.com - www.cuppone.com...
Need help?
Do you have a question about the Tiziano and is the answer not in the manual?
Questions and answers