Automatic closing time setting

5. Press „+" and select
the required closing time:
1 = 30 sec.
2 = 60 sec.
3 = 90 sec.
4 = 120 sec.

2000 cycle alarm setting

After a period of time in use, regularly
check to see whether the door is level when
opening/closing, and whether the spring has
enough force to raise the door.
Add a suitable amount of lubricant to all
moving parts regularly.
1. Press „P" for
approx. 5 seconds.
4. Press „+",
the display is „1".
(1 = on)
26
6. Press „P" in order
to store the setting.
5 = 150 sec.
6 = 180 sec.
7 = 210 sec.
8 = 240 sec.
(maximum)
2. Press „+"
(press several times if necessary)
until „7" is displayed.
5. Press „P" in order
to store the setting.
7. Conclude programming
(refer to page 27,
method 2)
or
proceed with the next
setting.
NOTE
If this function is activated, after 2000 cycles the door
operator will indicate with a short whistling tone at regu-
lar intervals that door maintenance must be carried out.
To end the alarm tone
Switch the power supply off and then on again, or press
the „P" button for the door for 5 seconds.
3. Press „P",
the display is „0".
(0 = off = factory setting)
6. Conclude programming
(refer to page 27, method 2)
or proceed with next setting.