Technical Specification; Installation Considerations - Hans Grohe AXOR Trim Kits 39224 0 Series Installation Instructions / Warranty

Table of Contents

Advertisement

Technical Specification

Recommended operating pressure
Recommended hot water temp.
Flow rate
Hole sizes
valves
transfer valve
pull rod
*Know and follow all applicable local plumbing codes when setting the temperature on the water heater. In
Massachusetts, the water heater may be set no higher than 112
Important:
This valve is for use on vertical spray bidets only. It is not suitable for use on
other fixtures.
The transfer valve has an integral vacuum breaker.

Installation Considerations

For best results, Hansgrohe recommends installation by a licensed professional plumber.
The hot and cold valves require 1/2" supply lines, which are not provided by Hansgrohe.
Large differences in pressure between the hot and cold supplies should be balanced.
The hot and cold supplies must be thoroughly flushed before installation to prevent damage to the
valve cartridges.
2
45 - 80 psi
120
F - 140
o
2.2 gpm
1 1/4"
1 1/4"
3/8" min.
F*
o
F.
o

Advertisement