Panasonic PN25168-NZ Installation Manual page 17

Table of Contents

Advertisement

 PoE power supply is impossible.
Power is not supplied to a Powered Device.
 If you use an STP cable, PoE power supply may not be possible depending on
the installation environment. In such cases, use a UTP cable.
 Is a CAT5e or better straight cable (RJ45-8/8) used?
 Is the cable connected to the port 1–12 that supports PoE power supply?
 Ensure that either the port alone or the entire equipment is not overloaded.
 Is the Powered Device connected to the port compliant with the IEEE802.3at
standard or IEEE802.3af standard?
Port LIM. LED is blinking in green:
 Ensure that the total power supply demand from PoE-powered devices does
not exceed 112 W or 80 W.
 If the supply power for the entire device is going to be used at 112 W or less,
use it in an area where it is 0 to 40°C.
 If the supply power for the entire device is going to be used at 80 W or less,
use it in an area where it is 0 to 50°C.
When the power supply is suddenly shut off:
 Confirm that a single port is not overloaded [Port LED (right) is not blinking in
Green], or that the power supply capacity for the device overall is not being
exceeded (PoE LIM. LED is not blinking in green).
* For the configuration and management methods, please see the
PDF version of the Operating Instructions on Panasonic's website.
17