PED4000 / PED5000 Series with M61
Alarmed Exit Devices
Installation Instructions
4
Cylinder Installation or Replacement (continued)
C
Battery
Box
D
Battery
Box
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2023, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
c
Cylinder (or foam plug)
a
Switch
Actuator
Cylinder
Nut
b
a
Cylinder
d
b
Switch
Actuator
c
Cylinder
Nut
Remove the original cylinder (or foam plug, if
ordered without the cylinder):
a. Remove the battery box to expose the rear side
of the cylinder side. Use caution not to damage
any wire or switch when opening the battery
box as it is still connected to the assembly with
the battery terminal wires.
b. Remove the cylinder nut and switch actuator.
c. Remove the original cylinder (or foam plug).
Install the new cylinder:
a. Install the new cylinder to the insert sub-
assembly with the keyway closest to the switch
end.
b. Reinstall the switch actuator with its legs on
opposite sides of the toggle switch on the
alarm board.
c. Reinstall the cylinder nut, then tighten.
d. Replace the battery box.
5
FM618 01/23
Need help?
Do you have a question about the Corbin Russwin PED5000 Series and is the answer not in the manual?
Questions and answers