PED4000 / PED5000 Series with M61
Alarmed Exit Devices
Installation Instructions
3
Door Preparation and Handing
Verify hand and bevel of door. Exit devices are always reverse bevel and are mounted on the
inside of the door.
Left Hand
Reverse Bevel
Hinges Left.
Open Outward
LHRB
Outside View
4
Cylinder Installation or Replacement
Note: If the cylinder is factory installed, go to Step 5 Installation Instructions (for retrofi t kit) on page 6.
A
Remove the battery and the battery box screws.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2023, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
PED5200 M61 LHRB
shown
Inside View
B
Disconnect the wire harness.
Right Hand
Reverse Bevel
Hinges Right.
Open Outward
RHRB
Outside View
4
PED5200 M61 RHRB
shown
Inside View