Section 5: Slideout Systems
Excessive
4
Major
Battery Volt-
age
6
Minor
Park brake LED flashing
Low voltage LED flashing
Preventative Maintenance
The Power Gear® slideout system requires very little maintenance. Read and follow these
procedures:
When the room is extended, visually inspect the slide rail assemblies. Check for
excess buildup of dirt or foreign material; remove any debris that may be present.
If the system squeaks or makes any noises, blow out any debris from the gear rack
arms and apply a dry lubricant to prevent and/or stop squeaking.
Refer to the Power Gear® website
Override Modes:
In the event of component failure or loss of system power, your slideout can be manually
overridden and retracted for travel.
Emergency Retract Mode
NOTE: During the override procedure, the unit will exit this mode if the
room has not been moved for two (2) minutes or if a fault is detected during
room movement. The Fault Code (RED) and Room or Lock Movement
(GREEN) LEDs will flash rapidly for 10 seconds to indicate the override
procedure failed. After 10 seconds of flashing, the control will automatically
default to FAULT CODE 1. Programming must be restarted.
72
Maintenance Record
-Bad or loose connec-
tion
-Defective harness
-Open or shorted motor
Supply voltage to con-
trol box is 17 0 V DC
or greater
-Parking brake not set
(if applicable)
-Ground signal lost at
park brake control
Incoming violated to
control box is below
12.0 VDC
www.powergearus.com
Table of Contents
-Check all connections at
control box and motor.
-Check the harness for bro-
ken wires.
-Put 12.0 VDC direct to
the motor. If it does not run
replace the motor.
Check 2-pin power con-
nector at control box. If
the voltage is 17. VDC or
higher, contact O.E.M for
power and ground supplies
-Set parking brake (if ap-
plicable)
-Check for continuity to
ground on wire plugged
into park brake connector at
control box.
Check 2-pin power connec-
tor at control box. If voltage
is below 12.0 VDC contact
O.E.M for power and ground
supplies.
for additional information.