7.
The GREEN LED should be solid ON when room is in
motion.
8.
Release the OUT button when the room is fully extended
or the IN button when fully retracted, and stops moving.
9.
Turn OFF the on/off switch or key.
Fault Diagnostics / Troubleshooting:
The control has the ability to detect and display several faults.
When a fault is detected, room movement stops and two different LEDs will flash in a pat-
tern.
The RED FAULT CODE LED (Fig 4) will flash a number of times corresponding to a spe-
cific fault code (refer to the Fault Code Chart).
The GREEN ROOM MOVEMENT LED (Fig 4) will flash GREEN a number of times cor-
responding to which motor has the associated fault.
Example: (4) RED flashes and (2) GREEN flashes indicate a motor fault on motor 2.
MAJOR and MINOR faults; faults must be cleared for the room to operate normally.
MINOR faults can be cleared by pushing and releasing the IN or OUT buttons on
the wall touchpad (Fig 4).
MAJOR faults must be cleared by pushing and releasing the SET STOPS/CLEAR
FAULTS button located on the back of the wall touchpad (Fig 2).
NOTE: For MAJOR faults, the control must be overridden by following the
EMERGENCY RETRACT MODE in the OVERRIDE MODES section.
Fault Codes
F a u l t
F a u l t
Code
Type
Description
Stops not
1
Major
programmed
2
Minor
System Fault
Maintenance Record
Section 5: Slideout Systems
Possible Cause
-Stops have not been
set
-Stops were cleared
-Stops were improperly
set
-Obstruction present
-Excessive system drag
Table of Contents
Possible Solution
Steps need to be pro-
grammed by an authorized
service facility.
Run room in opposite direc-
tion. If it continues to move
in the opposite direction,
remove obstruction, exces-
sive weight in room or repair
of damaged component. If
room stops moving in oppo-
site direction, observe fault
code and refer to this chart
71