Section 7: Fuel & Propane System
LP Gas Container Overfill
Never allow your propane tank to be filled above the maximum
safe level as indicated by the fixed liquid level gauge. Do not
allow the visible gauge to be used for filling. Overfilling the
propane container above the liquid capacity indicated on the
container, could allow liquid propane to enter the system that is
designed for vapor only creating a hazardous condition.
The propane piping system is designed for use with
"Shut off for re-fueling"
propane only. Do not connect natural gas to this system.
Label
This label should be kept permanently affixed to your RV.
(label appearance may not
Refer to your Warranty Packet for more information on the LP
be exact)
gas system components.
Maintenance
Propane gas is normally non-corrosive - you need not worry
about the inside of your container. However, the outside should
be kept free from rust by a periodic coat of paint in a light reflec-
tive color. Rust, scratches and/or dents can affect the safety of
the cylinder. Inspect the cylinder at regular intervals.
Ifs a problem, have it evaluated by a qualified technician and
discard it. DOT requires that a visual inspection be made prior
to each filling.
Any cylinder that has been exposed to fire, leaks or seems dam-
aged should not be refilled.
Do not attempt to repair any containers, container valves, regu-
lator or appliances by yourself. Use only trained certified pro-
pane gas service technicians to perform repairs.
"Do not fill to more than
Propane Cylinder Recertification
80%" Label
DOT cylinders may only be used for 12 years after their manu-
(label appearance may
facture date (the number of years for certification may vary in
not be exact)
your area). After that, the cylinders must be "recertified" which
provides another five years of use.
The cylinders can be recertified every five years thereafter. Federal DOT (Department of
Transportation) regulations require periodic inspections and re-qualifications of the propane
cylinders. DO NOT USE damaged or rusted containers.
Verify with your local propane dealer that all required inspections and certifications have
been completed on the propane cylinder within the correct time period before refilling the
cylinder. Have the LP system checked for leakage each time a cylinder is refilled or after
any part of the propane system has been disconnected.
Hoses, Pipes, Tubes and Fittings
The hoses, pipes, tubes and fittings used in your propane system are designed to withstand
pressures exceeding those of the propane system. However, because environment and time
can both contribute to the deterioration of these components, they must be inspected for
wear at regular intervals.
Be sure to inspect the hose before each season and when having the tank refilled. Look for
signs of deterioration such as cracks or loss of flexibility. When replacing the hose or other
propane components, make sure to always replace them with components of the same type
and rating (check with your dealer).
Fittings are used to connect the various system components to each other. The P.O.L. fitting
98