RV-C Bus Communication:
RV-C is a communications protocol based on CAN that is used for
control, coordination, and diagnostics.
1. By changing the FRESH/GREY/BLACK to zero senders, you
are disabling that sender's updates over the RV-C bus as
well.
2. The primary display has priority over the RV-C bus to check
levels. The secondary display will wait until the primary
display releases the bus before getting level readings.
3. The RV-C has a 4-pin connector as shown in the red box.
The connector pins conform to the RV-C standard.
4. Some displays have a wired connection as shown in the
red box in the image below. If this is what your display has,
connect the wiring according to the following table.
Wire colour
Black
Blue
White
709-RVC NLP Manual
Note: Anyone that intends on
connecting to the RV-C bus
should have a knowledge of
the RV-C specification. For
more information on RV-C
protocol go to: http://www.
rv-c.com
The sensors use a default
source address of 72 and
SPN-ISB instances are 0 for
fresh, 1 for black, 2 for grey.
Function
Ground
CAN Low (-)
CAN High (+)
Page 7