Lighting The Burners - CDA HG7501 Series Instructions For Installation, Use And Maintenance Manual

Built-in cooking hob
Table of Contents

Advertisement

LIGHTING THE BURNERS

To ignite the burner, the following instructions
are to be followed:
1.
Press in the corresponding knob and turn
counter-clockwise (fig. 3) to the full flame
position marked by the "
2); hold the knob in until the flame has
been lit.

In the case of a mains failure light the
burner with a match or lighted taper.
2.
Wait for a few seconds after the gas
burner has been lit before letting go of
the knob (valve activation delay).
3.
Adjust the gas valve to the desired
position.
If the burner flame should go out for some
reason, the safety valve will automatically
stop the gas flow.
To re-light the burner, return the knob to
the closed "
" position,
1 minute and then repeat the lighting
procedure.
Note:
If your local gas supply makes it
difficult to light the burner with the knob set
to maximum, set the knob to minimum and
repeat the operation.
Fig. 3
" symbol (fig.
wait for at least
DUAL BURNER - SOME MODELS ONLY
The Dual Burner is a very flexible burner which
allows different regulations and optimal
cooking.
It comprises one inner and one outer crown:
the inner and outer crown can be used
together or separately
The Dual burner is
separate knobs:
one
knob
for
only
("
" symbol identifying the
control knob);
one knob for the outer crown
("
" symbol identifying the control
knob).
The Dual burner can be used:
as a small burner (flame produced only
by the inner crown);
as an ultra-rapid burner (flame produced
only by the outer crown);
as a high-power burner (all flames
produced simultaneously by inner and
outer crown).
IMPORTANT: After using
the dual burner check both
the control knobs are in
the closed "
.
controlled by two
the
inner
crown
only
" position.
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hg7501ss

Table of Contents